Midco ECONOMITE F400B-33 Installation And Service Instructions Manual Download Page 7

PILOT GAS

PRESSURE

ORIFICE

DIAMETER

APPROX.

CAPACITY

NOMINAL BTU/Cu. Ft.

NATURAL-1000           PROPANE-2500

2.5"-4.0" W.C.            2.25"-3.5" W.C.

#55 WIRE DRILL

.052 DIA.

7000

TABLE 3: 

Pilot Specifications

X MOTOR, BLOWER INTERLOCK &

CENTRIFUGAL ACTUATOR

NOTE: BEFORE SERVICING, mark with a scribe line or
measure opening of primary air controlling shutter, so
that it can be reset to its original position following
servicing.

Cleaning of the blower wheel is usually the only

service required. Need for cleaning is indicated if the
character of the flame indicates a deficiency of air. Motor
cooling air vents if present should also be cleaned at this
time.

The blower side plate, motor and wheel are removed

as an assembly. Disconnect the motor wires from the
motor terminal strip. Disconnect the motor conduit from
the motor and remove the side plate screws.

The blower wheel is equipped with a spring loaded

centrifugal actuator to operate an electrical interlock
switch so as to prevent the burner from firing if the blower
wheel is not running at its operating speed. When the
motor is off, the actuator spring forces the disk against
the switch plunger to push it past its operating point.
When running, the actuator pulls the disk clear of the
plunger.

To make a specific test of the interlock circuit:

1.

Turn burner power OFF.

2.

Turn  Manual  Gas  Cock Knob on Combination
Valve to OFF.

3.

Disconnect the motor wire from the motor  relay
to keep the motor off.

4.

Turn  burner  power  ON  and  set the operating
control  to  ON  or  thermostat  to  call  for heat.
Check  for  24V  between the Electronic Control
25V  and 25V GND terminals.
A. No voltage: Interlock circuit OK.
B. Voltage present: check that switch bracket is

screwed  down  tight  (see Figure 6).   If so,
without disconnecting switch wires, remove 
switch bracket and manually depress switch
plunger.  If  voltage  is still present, or if the
plunger   has   to  be  depressed  to  where
dimension"A"  of Figure 6 is less than 9/32"
when switch clicks over, replace the switch.

5.

If the switch tests OK, check dimension "A" of 
Figure 6 as follows:
Switch plunger free………………9/32 to 11/32"
Disk free…………………………...7/32 to 1/4"
Disk held all the way in………….15/32" min.

6.

If plunger dimension is wrong, replace switch. If
disc dimension is wrong, check that the actuator
operates  freely  with  a  minimum movement of
1/4"  from the free position. If movement is  OK,
reposition  blower  wheel  on  motor shaft. If not,
replace wheel.

FIGURE 6 Motor, Blower and Interlock Assembly

-7-

Summary of Contents for ECONOMITE F400B-33

Page 1: ...s or in the absence of local codes with Installation of Domestic Gas Conversion Burners ANSI Z21 8b 1993 and National Fuel Gas Code ANSI Z223 1 1992 or latest edition s available from American Nationa...

Page 2: ...is of one square inch free area per 1 000 BTU of the total input rating of all gas utilization equipment in the combined space One grille should be located within 12 inches of the ceiling the other wi...

Page 3: ...at transfer to the primary surfaces of the heat exchanger In most cases the existing combustion chamber liner formerly used for oil burner can be used if in good condition In the case of wet base boil...

Page 4: ...ing close to burner as shown in Figure 5 Use pipe joint compound approved for use with Liquid Petroleum Gases Piping must comply with local codes To obtain the maximum firing rate of 700 MBH the NATUR...

Page 5: ...bination Valve to OFF close Pilot Manual Shut Off Valve turn burner power on and set operating control to ON or thermostat to call for heat Let the blower run long enough to accomplish four air change...

Page 6: ...r Switch are turned OFF before removing any parts for service WARNING All cover plates enclosed and guards must be in place at all times except during maintenance and servicing IX PILOT The pilot is o...

Page 7: ...e switch plunger to push it past its operating point When running the actuator pulls the disk clear of the plunger To make a specific test of the interlock circuit 1 Turn burner power OFF 2 Turn Manua...

Page 8: ...justable for outlet pressure range of 2 0 W C to 5 0 W C Outlet pressure settings must be checked while the gas is flowing To adjust outlet pressure remove the seal cap for access to the adjusting scr...

Page 9: ...D AND THE BURNER IS LOCATED IN A BASEMENT CRAWL SPACE OR CONFINING SPACE CONTACT YOUR GAS SUPPLIER ABOUT INSTALLING A GAS LEAK WARNING DEVICE PROPANE GAS IS HEAVIER THAN AIR AND CAN SETTLE IN LOW AREA...

Reviews: