IV Vent Connector 

Continued

V Electrical

The Vent Connector shall be firmly attached to draft hood outlets and flue collars. Joints

between sections of connector piping shall be fastened by sheet-metal screws or other approved
means. The Vent Connector shall be supported for the design and weight of the material
employed to maintain clearance and prevent physical damage and separation of joints.

CAUTION: Do not add any power consuming devices in the low voltage circuit as

overloading of the transformer can result. Do not use Motor Relay to operate any exter-
nal devices as overloading of motor relay contacts can result.
Note:

If any of the original wiring as supplied with the conversion burner must be replaced, it

must be replaced with type TFF wire or its equivalent.
Installation wiring and grounding of the burner must conform to local codes, or in their absence
in the 

United States to National Electric Code, ANSI/NFPA No. 70-latest edition

; in 

Canada,

to Canadian Electrical Code Part 1, CSA Standard C22.1.

Use 14 gauge copper wire for line voltage wiring. Be sure to hook up to a permanently live

circuit. Provide a fused on-off disconnect switch carrying a minimum 3 amp fuse.

The frame of the burner must be well grounded. A terminal is provided in the control box for

positive grounding where insulated pipe couplings are used or where any doubt exists regarding
grounding sufficiency.

Confirm that the polarity is correct—hot wire strip terminal 

1

, neutral 

2

— and that the neutral

line is not subject to induced low voltage (check 

2

to earth ground) from other equipment as that

can cause the electronic flame safeguard to malfunction.

Each installation must include suitable limit controls. Existing oil burner combination limit and

operating controls are normally 

NOT SUITABLE

for gas burner use.

Set the thermostat heat anticipator for the total current draw handled by the thermostat. The

current draw of the ECONOMITE 24V operating circuit is 0.9 amps.

CAUTION: Label all wires prior to disconnection when servicing controls. Wiring

errors can cause improper and dangerous operation. Verify proper operation after servic-
ing.

Figure 3: Draft Hoods

Figure 4: Location for Barometric 

Draft Regulator

Figures 3 and 4: Copyright by the 

American Gas Association. Used by 

permission of the copyright holder.

Figure 5: Wiring Diagram

4

Summary of Contents for Economite DS24A

Page 1: ...ch hazards Affix this manual adjacent to the conversion burner CODE COMPLIANCE IS THE SOLE RESPONSIBILITY OF THE INSTALLER WARNING If the information in these instructions is not followed exactly a fi...

Page 2: ...0 square inches of the total input rating of all gas utilization equipment in the confined space One grille should be located within 12 inches of the ceiling the other within 12 inches of the floor If...

Page 3: ...zzle ribbon is free of for eign materials and also that the electrodes have not been damaged or displaced see Figure 7 WARNING The chimney shall be inspected for unsafe conditions such as deteriorat e...

Page 4: ...e sure to hook up to a permanently live circuit Provide a fused on off disconnect switch carrying a minimum 3 amp fuse The frame of the burner must be well grounded A terminal is provided in the contr...

Page 5: ...OPANE gas only and should be used only with the gas specified on rating plate A Standard Model DS24A Economite is shipped ready for NATURAL gas As shipped it is field convertible to PROPANE gas see Ta...

Page 6: ...or capacity rating of the gas utilization equipment Refer to Section VII Main Gas Spud and Table 3 5 RESET the Electronic Control by setting the operating control to OFF or the thermostat below room t...

Page 7: ...ng and shut off procedure refer to CONSUMER INSTRUCTIONS or to the instruction plate mounted on the burner DANGER Be sure that the Main Manual Shut Off Valve Combination Valve and Burner Power Switch...

Page 8: ...stment an overfire condition could result when pressure returns to normal particularly if the regu lator adjustment screw is bottomed out ALWAYS confirm that at least the minimum rated gas pressure is...

Page 9: ...OR REPAIR WARNING If PROPANE gas is used and the burner is located in a base ment crawl space or confining space contact your gas supplier about installing a GAS LEAK warning device PROPANE gas is hea...

Page 10: ...ol b Between Electronic Control high voltage terminal and Spark Electrode Wire insert head of 8 x 3 4 or longer round head screw into snap terminal inside right angle rubber boot No spark broken wire...

Reviews: