Midco
®
International Inc. -
4140 West Victoria Street - Chicago, Illinois 60646 - toll free: 866 705 0514
tel: 773.604.8700 - fax: 773.604.4070 - web: www.midcointernational.com - e-mail: [email protected]
18
Printed in USA
8471 34
ISO
9001
C
O MPAN
Y
R
E
G
IS T ER
E
D
1219
Figure 9 shows the assembly of a typical HMA 2 and HMA 2A direct
fi
red burner assembly for both
“in
fi
eld” and factory assembly line.
A)
1-1/2
″
Inlet Flange With Pilot Mount or Blank Plate Hardware Required:
Furnace
Cement
(See Notes # 1)
8 Stainless Steel Pcs of 10-24 X 3/8
″
Slotted Round Head Screw,
10-24 Hex Nut, 10-24 Lock Washer (Rivet Gun Required)
3 Pcs 5/16
″
X 2
″
Hex Cap Screws
3 Pcs 5/16
″
Lock Washers
3 Pcs 5/16
″
-18 Nuts
B)
Blank Flange With Blank Plate or Pilot Mount Plate Hardware Required:
Furnace
Cement
(See Notes # 1)
8 Stainless Steel Pcs of 10-24 X 3/8
″
Slotted Round Head Screw,
10-24 Hex Nut, 10-24 Lock Washer (Rivet Gun Required)
3 Pcs 5/16
″
X 1-3/4
″
Hex Cap Screws
3 Pcs 5/16
″
Lock Washers
3 Pcs 5/16
″
-18 Nuts
Notes:
1)
Furnace cement is to be applied between the casting and either blank plate, pilot plate and
end
fl
anges only, not between ba
ffl
es and end plates.
2) The hardware listed on instructions A and B applies to each end of any size burner with such
con
fi
guration.
3) For de
fi
nition and views of burner section, plates,
fl
anges, or hardware refer to page 16 and
17 of the Installation and Service Instructions manual.
4) Burner drawing symbols represent a view of the burner from side opposite the
fl
ame exit.
5) In the absent of a rivet gun, use the hardware speci
fi
ed on these instructions, stainless steel
hardware is highly recommended.
UNDER NO CIRCUMSTANCES SHOULD STANDARD GRADE
OR ALUMINUM RIVETS BE USED.
6) Hardware used between burner sections is the same as the hardware used on Instructions B.
7) Pilot hardware Is Included with the pilot assembly.
8) If Installing mounting brackets, they must be Installed on the exterior side of the Inlet or blank
fl
ange.
UNDER NO CIRCUMSTANCES SHOULD THEY BE INSTALLED
BETWEEN THE FLANGE AND THE BURNER CASTING.
___________________________________
Burner Assembly Instructions
A
B
Burner Assembly
Instructions
Figure 9
-
Typical HMA 2 & HMA 2A 6
″
Direct Fire Burner Assembly