POWER  SUPPLY  REQUIREMENTS  AND  SETTINGS

IMPORTANT: 
PLEASE READ THIS SECTION CAREFULLY BEFORE CONNECTING YOUR
POWER SUPPLY TO THE AC MAINS FOR THE FIRST TIME.

The available power supply for  the  VENICE 240 and 320 mixer is named EPS1200.  

Description

All Venice consoles are equipped with an internal power supply. When a back-up supply or an
external power supply for any reason is needed the EPS1200 is the unit of choice. The EPS1200
takes over the supply of the console and the internal supply is free running for back-up reasons
or can be turned off by pulling the mains cable or by pushing the power on switch at the console.
In the very unusual case, that the external (EPS1200) supply fails, the internal (console) supply
can take over if powered. 
The EPS1200 power supply is a  conventional  linear unit, which produces DC - voltages  by
rectifying, smoothing  and  regulating  AC - voltages  from  the secondary windings of the mains
transformer. 
The  unit  dissipates  a  certain small amount of heat  which should not be considered abnormal.
For safety in thermal critical enviroment, a fan is installed which is thermally controlled and
provides forced front to rear cooling if the internal heat-sink reaches the threshold temperature.
The unit is designed for installation in 19" racks, but may be  operated  free-standing  as  well.
Please refer to  the section ‘Recommendations for installation’.  
Indicators are provided on the  front  panel  to  show correct operation of the power supply.

In addition,  the power supply unit is provided with a delayed turn-on circuit, which operates
relays on all VENICE balanced XLR outputs,  preventing the outputs of the console being
operated before the power supply  is  at its correct operating voltages.  This helps to prevent
any transients reaching amplifiers and giving  turn-on ‘thumps’.  

3

Summary of Contents for EPS 1200

Page 1: ...Klark Teknik Group Klark Teknik Building Walter Nash Road Kidderminster Worcestershire DY11 7HJ England Tel 44 0 1562 741515 Fax 44 0 1562 745371 Email pro_audio_group compuserve com Website midascons...

Page 2: ...let consult an electrican for replacement of the obsolete outlet 1 Security regulations as stated in the EN 60065 VDE 0860 and the CSA E60065 00 have to be obeyed when servicing the appliance 2 Use of...

Page 3: ...t which produces DC voltages by rectifying smoothing and regulating AC voltages from the secondary windings of the mains transformer The unit dissipates a certain small amount of heat which should not...

Page 4: ...anges DO NOT CHANGE THE VOLTAGE SETTING WITHOUT FIRST UNPLUGGING THE MAINS LEAD TO AVOID RISK OF FIRE ONLY REPLACE WITH THE CORRECT VALUE FUSE AS INDICATED ON THE UNIT FOR THE SPECIFIC VOLTAGE SETTING...

Page 5: ...ean audio signals Ground loops may occur where signal processing equipment patched to the console has it s common signal earth to the equipment chassis The ground loop is formed if this chassis and th...

Page 6: ...monitoring the correct function of these voltages If any of these voltages is not available or low powered the according LED will go off The fail LED is monitoring if one of the XLR outputs except 12V...

Page 7: ...Klark Teknik Group Klark Teknik Building Walter Nash Road Kidderminster Worcestershire DY11 7HJ England Tel 44 0 1562 741515 Fax 44 0 1562 745371 Email pro_audio_group compuserve com Website midascon...

Page 8: ...mplett spannungsfrei zu schalten mu der Netzstecker gezogen werden WICHTIGE SERVICEHINWEISE 1 Bei Reparaturarbeiten im Ger t sind die Sicherheitsbestimmungen nach EN 60065 VDE 0860 einzuhalten 2 Bei a...

Page 9: ...h zu einer unn tigen thermischen Belastung des Netzteiles f hren Aus diesem Grund ist ein extrem laufruhiger und temperaturgesteuerter L fter installiert der einen Luftstrom von der Frontseite zur R c...

Page 10: ...VOR NDERUNG DER NETZSPANNUNGSEINSTELLUNG MUSS DAS GER T DURCH ZIEHEN DES NETZSTECKERS SPANNUNGSFREI GESCHALTET WERDEN DIE NETZSICHERUNG DARF NUR MIT DEM KORREKTEN WERT UND ENTSPRECHENDER TYPE ERSETZT...

Page 11: ...sich wenn dieses Chassis und das Chassis des EPS 1200 in elektrischem Kontakt sind z B ber gemeinsame Metall Befestigungsschienen im Rack Diese Situation l sst sich durch den auf der Frontseite des E...

Page 12: ...orhan densein dieser Spannungen an Ist eine dieser Spannun gen zu niedrig oder f llt ganz aus erlischt die zugeh rige LED Die fail LED leuchtet auf wenn eine der wichtigen Betriebsspannungen 17V und 4...

Page 13: ...rk Teknik Group Klark Teknik Building Walter Nash Road Kidderminster Worcestershire DY11 7HJ England Tel 44 0 1562 741515 Fax 44 0 1562 745371 Email pro_audio_group compuserve com Website midasconsole...

Page 14: ...s sont sp cifi es par les directives EN 60065 VDE 0860 IEC 65 et CSA E65 94 doivent tre observ es lors de la r paration de l appareil 2 L usage d un transformateur d isolation est obligatoire pendant...

Page 15: ...e ceci afin d viter d endommager les haut parleurs par des bruits de commutation in vitablement caus s par le changemement rapide d alimentation L alimentation EPS1200 est une unit lin aire convention...

Page 16: ...LE R GLAGE DE LA TENSION SANS AVOIR AU PR ALABLE D BRANCHER LE CORDON SECTEUR POUR VITER TOUT RISQUE D INCENDIE REMPLACER LE FUSIBLE UNIQUEMENT PAR UN FUSIBLE AYANT LA MEME VALEUR COMME INDIQU SUR L...

Page 17: ...naux audio Des boucles de masse peuvent se produire si un appareil de traitement du signal reli la console est lui aussi mis la masse par son ch ssis La boucle de masse se forme alors si ce ch ssis et...

Page 18: ...as correcte le voyant sera teint Le voyant Fail indique qu une des sorties XLR n est pas correcte ceci ne prend pas en compte la tension 12 Vt disponible sur la PIN 4 Si un voyant fail est allum une v...

Page 19: ...in 3 17V 1 5A Pin 4 12V 1 0A Pin 5 48V 0 3A Pin 6 Ground Max length of the XLR cable connection 10 mtr 32 81 feet Protection Current limiter turn on delay Cooling Thermal controlled fan front to rear...

Reviews: