Version 

Modified content 

Release time 

1.0 

First edition 

2019.05 

1.1 

Parameter modification 

2019.12 

 
 
The information provided in this document is provided "as is" and is subject to change in future 
versions without notice. In addition, to the maximum extent permitted by applicable laws, Micsig 
does  not  provide  any  express  or  implied  guarantees  for  this  manual  and  any  information 
contained in it, including but not limited to implied guarantees for merchantability and suitability 
for specific purposes. Micsig is not responsible for errors or accidental or consequential damages 
caused  by  the  provision,  use  or  use  of  this  document  or  any  information  contained  in  it.  If  a 
separate  written  agreement  has  been  reached  between  Micsig  and  the  user  that  contains 
warranty  terms  related  to  the  content  of  this  document,  but  the  warranty  terms  conflict  with 
these terms, the warranty terms in the separate agreement shall prevail. 
 
 
 
 

 

Summary of Contents for CP2100A

Page 1: ...CP2100A CP2100B ...

Page 2: ...l and any information contained in it including but not limited to implied guarantees for merchantability and suitability for specific purposes Micsig is not responsible for errors or accidental or consequential damages caused by the provision use or use of this document or any information contained in it If a separate written agreement has been reached between Micsig and the user that contains wa...

Page 3: ...3 10 1 Product Introduction 5 2 Appearance 5 3 Specifications 6 4 Instructions 9 5 Maintenance 9 ...

Page 4: ...touch the measured conductor and sensor head during measurement Do not use in a humid environment Do not touch the instrument or the measured object with wet hands Please use this product within the range allowed by the end user Please use this product as required Please ground this product through the USB power cord ...

Page 5: ...ters via connector The maximum current can be measured to 100Apk 70Arms it has 2 models CP2100A and CP2100B CP2100A can measure bandwidth to DC 800KHz CP2100B can measure bandwidth to DC 2MHz 2 optional measuring ranges 10A and 100A Automatic and manual zero adjustment powered by USB no additional power supply making measurement more convenient Often used in motor drives industrial frequency inver...

Page 6: ...k 70 7Arms DC ACpk 200Apk pk 70 7Arms AC Maximum working voltage CAT III 300V CAT II 600V Maximum floating voltage CAT III 300V CAT II 600V Maximum conductor diameter 13mm Overload indication The buzzer sounds long and the button light flashes Supplied power DC 5V Probe head size 11 6 1 2 5cm Control box size 10 8 5 6 2 6cm Length 228cm Weight 290g Package weight 1000g Package dimensions 29 5 23 6...

Page 7: ...7 10 Maximum current VS Frequency curve Amplitude frequency characteristic curve CP2100A ...

Page 8: ...8 10 Amplitude frequency characteristic curve CP2100B DC signal linearity 0 01V A ...

Page 9: ...sition of the probe do not move it in a large range after the zero adjustment is completed 5 Open the jaws to clamp the conductor under test according to the direction indicated by the clamp head Note If the measured current flows in the opposite direction to the clamp head the output will be negative 6 Adjust the oscilloscope to get the best waveform Note When the current exceeds the range the bu...