background image

ACP1000 AC Current Probe

It tests the circuit current safely and directly without disconnecting the 
circuit. This method permits a safe,easy and portable current measurement.

The ACP1000 AC current probe is clamp-on core design.

•  Good appearance
•  Clamp-on core design safer, easier installation without disconnecting 
    the circuit to test
•   Current or three specs voltage outputignal

•   Current, ower energypower factor correction device
•   Industrial control device
•   Oscilloscope andharmonic wavesnalyzer

•  Current range: 0.1A-1000A
•  Maximum working current: 2000A
•  Output signal: mV/A 
•  Operating frequency: 10Hz–100kHz 
•  Maximum accuracy: 1%
•  Operating Temperature: -15

º

C to 60

º

C

•  Safety class: CAT III 600V
•  Maximum conductor diameter: 2.05 inches (52mm)
•  Dimensions: 4.37 in. x 8.50 in. x 1.77 in. (111x216x45mm)
•  Output cable: 1.5m BNC insulated coaxial output cable can connect 
   directly to an oscilloscope, and can be used with Multimeters with 
   optionalBNC/Banana adapter.
•  Environmentl compliance: RoHS compliane

PERFORMANCES

Notes:Accuracies are given for 48 Hz to 65Hz;the ambient temperature of 25º C±3º C.

Model

Input current

(A)

Output signal

Frequency

(

Hz

)

Secondary burden

(Ohms)

Accuracy class

ACP1000

0

.

1

-

10

100mV

/

A

10

-

100K

100K

3

10mV

0

.

1

-

100

10mV

/

A

2

5mV

1

-

1000

1mV

/

A

1

1mV

FEATURES

APPLICATIONS

 

Shenzhen Micsig Instruments Co., Ltd.

Add: 

1F, Bldg A, Huafeng International Robot Industrial Park, Hangcheng

Avenue, Xixiang Sub-district, Bao'an District, Shenzhen, China

TEL: +86-755-88600880                       
WEB: www.micsig.com                        E-mail: [email protected]

SPECIFICATIONS

Ratio: 1000:1 ; Frequency: 50 Hz ; 
Burden 1 Ohms ;temperature 25º C.

CHARACTERISTIC PERFORMANCE CURVE

User Manual

0

100
90
80
70
60
50
40
30

δ

(

 

)

Phase

δ

(

 

)

-4

-3

-2

-1

1A

10A

100A

f( )

Amplitude f( )

I

I

I

%

%

I

-0.2

-0.1

0

100A

1000A

10000A

5

10

15

20

25

30

35

f( )

δ

(

 

)

Pha se

δ

(

 

)

Amplitude f( )

I

I

I

%

I

%

Micsig warrants that this current probe will be free from defects in materials 
and workmanship for a period of one(1) year. If any such product proves 
defective during this warranty period, Micsig, at its option, either will repair
the defective product without charge for parts and labor, or will provide a 
replacement in exchange for the defective product. Parts, modules and 
replacement products used by Micsig for warranty work may be new or 
reconditioned to like new performance. All replaced parts, modules and 
products become the property of Micsig.

Reviews: