3.2
Wiring
a)
Connect to appropriate power supply, the voltage should comply with the rated voltage of the
products.
b)
Earth the machine well.
c)
Wiring must be handled by a professional technician according to the circuit diagram.
d)
Set leakage protector according to the local code for wiring (leakage operating current ≤ 30mA).
e)
The layout of power cable and signal cable should be orderly and not affecting each other.
3.3
Electric wiring Diagram
For power supply: 400V 50Hz
Note: 1)
Must be hard wired, plug is not allowed.
2) The swimming pool heat pump must be earthed well.
3.4
References for protecting devices and cable specification
※
Above data
is subject to modification without notice.
Note:
The above data is adapted to power cord ≤ 10m. If power cord is
>
10m, wire diameter must be increased.
The signal cable can be extended to 50m maximumly.
MODEL
iMAX60
iMAX110
Breaker
Maximum Current (A)
23
45
residual-current circuit breaker (A)
30
30
Fuse (A)
23
45
Power Cord (mm
2
)
5×6
5×16
Signal cable (mm
2
)
3×0.5
3×0.5
Distribution Box(Customer prepare)
Power Cord
Swimming Pool Heat Pump Wiring Board
Power Supply
400V 50Hz
Breaker
Earthing
Fuse
H
E
A
T
P
U
M
P
MI
C
R
O
W
E
L
L H