I n s t a l l a t i o n a n d u s e r m a n u a l
|
15
HEA
T
PUM
P
M
IC
R
O
W
E
LL
H
P
C
O
M
P
A
C
T
5.5 Timer setting (Timer ON, Timer OFF)
By the timer function you turn on/off the device automatically.
In the STAND-BY mode (OFF) the „on“ time (Timer ON) can be adjusted: by pressing the
button, you enter the timer setting mode. By repressing the
button, you leave this mode. By
pressing the
buttons, you can set the „on“ hour. After the time expiry, the heat pump
automatically starts to operate. The time setting range is 1-24 hours.
In the operating status (ON), the „off“ time (Timer OFF) can be adjusted: by pressing the
button, you enter the timer setting mode. By repressing the button, you leave this mode. By
pressing the buttons
you can set the „off“ hour. After the time expiry, the heat pump
automatically turns off. The time setting range is 1-24 hours.
Note: It is not possibel to set the Timer ON and Timer OFF at the same time.
Note: The device does not have its own hours. The countdown of the timer starts immeddiately after
its setting.
Note: By pressing the
, button while the timer is in operation, the timer setting is cancelled.
5.6 Control panel lock
By keeping the buttons pressed for 5 seconds at the same time, the control panel gets
locked. To unlock the panel, do the same.
6. USE AND OPERATION OF THE DEVICE
6.1 Operating instructions
IMPORTANT:
For heating the swimming pool by the heat pump, the filtration pump must run and the water must flow
through the heat exchanger.
Never turn on the heat pump if it is without water and if the filtration device is not operating.
Never cover the heat pump - there must be air flowing.
Protect the heat pump from freezing. Eliminate the water from the filtration and from the heat pump, and
prepare the product for the winter time.
At low surrounding temperature level (below 10°C) and high relative air humidity level (when/after raining),
the evaporator may get frozen. It is not economical to use the heat pump under such conditions.
6.2 Setting of the
operating status by the by-pass
If the by-pass is a part of the filtration circuit (it is not included in the heat pump package), it is
possible to set the optimal operation of the heat pump after putting it into operation.
Use of the by-pass
The by-pass consists of 3 valves connected as shown in the picture below. On the right hand side,
there is an inflow from the filtration pump and on the left side, there is a reversible tube back
to the swimming pool.
back to the swimming
pool
from the filtration
pump
Connection of the by-pass
VALVE
VALVE
VALVE