MDS 05-2415A01, Rev. A
PROGRAMMING AND DIAGNOSTICS
3-7
•
Time-Out Timer length = 30 sec
•
Soft Carrier Dekey = 0 ms
•
Squelch Tail Eliminator = On
The transceiver is to be programmed to operate in a system requiring the following
parameters:
•
Transmit frequency = 428.8375 MHz
•
Receive frequency = 438.8375 MHz
•
Time-Out Timer length = 94 sec
•
Soft Carrier Dekey = 4 ms
•
Squelch Tail Eliminator = off
•
Loopback Code = 1234
The list of steps and commands below will program the MDS 4310 with the required values.
1.
Connect the HHT to the transceiver as previously outlined, and open the diagnostics
channel if necessary.
2.
Verify the current frequencies by typing
FRQ
+
ENTER
. Display will read:
TX FRQ = 428.01250
RX FRQ = 438.01250
3.
Program the new transmit frequency by typing
PTX
+
SPACE
+
SHIFT
+
428.83750
+
SHIFT
+
ENTER
. Be sure to include the decimal point and all trailing zeros.
The display will read
TX FRQ PRGMD TO 428.83750 MHZ
if the information was entered
correctly and accepted by the microcontroller.
4.
Program the new receive frequency by typing
PRX
+
SPACE
+
SHIFT
438.83750
+
SHIFT
+
ENTER
, again taking care to enter in all characters.
If the information was entered properly, and accepted by the microcontroller, the
display will read
RX FRQ PRGMD TO 438.83750 MHZ
.
5.
Program the time-out timer length by entering
PTOT
+
SPACE
+
SHIFT
+
94
+
SHIFT
+
ENTER
. The display will read
TIME-OUT TIMER SET TO 094 SECS
.
6.
Program the soft carrier time by entering
PSCD
+
SPACE
+
SHIFT
+
4
+
SHIFT
+
ENTER
.
Display will read
SOFT CARR. DEKEY SET TO 004 MS
.
7.
Disable the STE by typing
DSTE
+
ENTER
. The display will read
SQUELCH TAIL
ELIMINATOR OFF
.
8.
The information entered in can now be reviewed by using the
FRQ, TOT, SCD
and
STE
commands to review each setting.
9.
Enter the loopback code by typing
PLBC
+
SPACE
+
SHIFT
+
1234
+
SHIFT
+
ENTER
. The display will change and read
LOOPBACK CODE = 1234
.
10. Close the diagnostics channel by typing
CLOS
+
ENTER
before unplugging the HHT.
This completes the programming sequence.
Summary of Contents for MDS 4310
Page 27: ...1 14 GENERAL MDS 05 2415A01 Rev A This page intentionally blank ...
Page 45: ...2 18 INSTALLATION MDS 05 2415A01 Rev A This page intentionally left blank ...
Page 61: ...3 16 PROGRAMMING AND DIAGNOSTICS MDS 05 2415A01 Rev A This page intentionally left blank ...
Page 85: ...4 24 FIELD TESTS ADJUSTMENTS MDS 05 2415A01 Rev A This page intentionally blank ...
Page 87: ......
Page 95: ......
Page 99: ...6 4 TROUBLESHOOTING MDS 05 2415A01 Rev A This page intentionally blank ...
Page 103: ...A 4 APPENDIX A MDS 05 2415A01 Rev A This page intentionally blank ...
Page 107: ...B 4 APPENDIX B MDS 05 2415A01 Rev A This page intentionally blank ...
Page 111: ...C 4 APPENDIX C MDS 05 2415A01 Rev A This page intentionally blank ...
Page 117: ......
Page 120: ......
Page 121: ...E 4 APPENDIX E MDS 05 2415A01 Rev A This page intentionally blank ...
Page 123: ...H 2 APPENDIX H MDS 05 2415A01 Rev A This page intentionally blank ...
Page 125: ...I 2 APPENDIX I MDS 05 2415A01 Rev A This page intentionally blank ...
Page 129: ......