18 Microtek TMA1600 Installing and Getting Started
3. Using the scanner's top ruler as a reference point, adjust the target position so
that it is placed horizontally in the center of the glass surface.
Calibrating your target
1. With the target properly positioned in the scanner, turn on your scanner and let it
warm up for about five minutes.
2. Launch the Microtek Scanner ICC calibration program.
In Macintosh, locate the Microtek ICC Profile folder, and double-click the ICC
Profile icon. In Windows, select the Start menu, Programs, Microtek ScanWizard
Pro for Windows, then Microtek Scanner ICC Profiler.
3. The main dialog box appears. Set the appropriate parameters, click the Start
Profiling button, then follow the screen instructions to generate your ICC profile.
Select "Positive"
Select the date code and
target type to match
your target
Choose the scanner model
you are currently using.
6
5
1
0
4
3
2
1
2
3
4
5
6
0
Make sure the woman's
portrait lies towards the
right side of the scanner.
Please note that the
calibration window
on the
glass surface should be kept
clear and free from any
obstruction during scanning.