MAIN MENU

LIMITS

color

 Go

/

NoGo

MAX/MIN

indicating max or min value

FORMULA MODE

Ax

2

+Bx+C

TIMER MODE

saving or transfer data on timer

ERROR COMPENSATION

mathematical correction

TEMPERATURE COMPENSATION

manual correction 4 materials

RESOLUTION

selected up to 0.0001mm

AXIS MODE

normal or inverted

WIRELESS

modes of data transmition

USB

USB connection configuration

DEVICE SETTING

autostart, reset, password 

SCREEN SETTING

screen rotation, brightness

SOFTWARE

link to download app

MEMORY SETTING

folder configuration

DEVICE INFO

service info about device

MEMORY MANAGER

max 100000 values

folders system

transfering data from memory to PC

 

color indication Go/NoGo

mm/inch 

conversion

functions status

CALIBRATION STATUS

calibration date control

ZERO setting

Battery status

MENU NAVIGATION

Summary of Contents for 110181027

Page 1: ...MICROTECH SUB MICRON INTELLIGENT COMPUTERIZED MICROMETER HEAD Calibration ISO 17025 2017 ISO 9001 2015 USER MANUAL...

Page 2: ...has memory manger with possibility saving data to folders Separate Data s or Folders can be transfer Wireless to MICROTECH Software Windows Android iOS FORMULA MODE In Formula mode we use Ax2 Bx C Mai...

Page 3: ...ake a measurement Rotation the micrometer screw in the direction of convergence measuring surfaces using the ratchet For zero setting press the ZERO button on Touchscreen SWITCH ON DEVICE button push...

Page 4: ...inverted WIRELESS modes of data transmition USB USB connection configuration DEVICE SETTING autostart reset password SCREEN SETTING screen rotation brightness SOFTWARE link to download app MEMORY SET...

Page 5: ...FORMATS SAVING DATA TO XLS CSV FORMATS SAVING GRAPH VOICE MODE iOS up to 50m DATA TRANSFER DISTANCE FOR INTELLIGENT INSTRUMENTS All MICROTECH Intelligent instruments has internal memory You can collec...

Page 6: ...1 Go NoGo NoGo MATH ERROR COMPENSATION TEMPERATURE COMPENSATION RESOLUTION EXTRA Axis mode Selecting instrument resolution Selecting normal or inverted axis mode Re calculation value to calibration co...

Page 7: ...CALIBRATION DATE DEVICE INFO Saving or transfer data by Timer Select timer period For disactive reset to zero Information about firmware version and MAC adress for easy connection Link to page with MD...

Page 8: ...thout prior notice Edition M1030_0520 MICROTECH innovative measuring instruments 61001 Kharkiv Ukraine str Rustaveli 39 tel 38 057 739 03 50 www microtech ua tool microtech ua Free Software for Window...