1.Clean the oil from the measuring surfaces of micrometer by cloth.
2.If necessary, open the battery cover; insert the battery (type CR2032)
according to the polarity of the electrodes. Blinking display information
or absence suggests replacing battery. After battery replacement on the
screen will be ---------- indication. Press SET button for setting 0.000 .
3 Turn on the display by pressing 0/MODE button.
4 Check the setting display to zero. Contact with each other (or with setting
gauge) measuring surfaces of the anvil and the spindle, using the ratchet
and take a measurement.
Rotation the micrometer screw in the direction of convergence measuring
surfaces using the ratchet.
ip located at the end of screws, used only for reverse spindle.
5 For zero setting, press the O/MODE or SET button and hold it to reset to
Zero.
6 After switching on, the display shows the measured value of the metric/
English system of units. Press UNIT button to switch between metric/
English measurement systems.
7 After switching on, the display shows in absolute or relative terms. Press
O/MODE button to switch between absolute and relative measurement
8 During measure, thimble should rotate only by ratchet. Ensure contact of
workpiece with measuring surfaces of the micrometer so tightly to ratchet
cranked 2-3 times. Try to prevent warping measuring surfaces.
9 This micrometer has auto switch off function (10 min non using) ot press
UNIT button during 2 sec. to switch off.
10 After work the measuring surfaces of the micrometer wipe with a cloth
and apply anticorrosive oil.
WARNING !
- Avoid contact with the body electronics unit micrometer emulsions and oils.
- During the measurements, periodically check the zero setting micrometer.
- Do not make the rotation of the micrometer screw in close measuring surfaces using a thimble.
- Avoid shocks or falling, even with a small height.
- Do not disassemble or adjust the micrometer persons who unrelated to the repair.