background image

MICROTECH

MATHEMATICAL ERROR COMPENSATION

MENU SETTING

TEMPERATURE COMPENSATION

MENU SETTING

RESOLUTION

MENU SETTING

MAIN SCREEN INDICATION 

EXTRA (Axis mode)

MENU SETTING

Resolution selecting

Selecting normal or inverted axis mode 

(+/- value indication)

Selecting resolution of value on main screen and memory

Reading base reconnection for some 

types of calipers

mm/inch conversion

Re-calculation detail size to calibration conditions (20°C)

Manual Temperature setting

7 types of material for selection

7 types of material:

- glass, quartz, solid alloys

- granite, graphite

- Fe, NI, Fe alloys

- stainless steel

- cooper, Cu alloys

- alluminium, al alloys

- acrylic sheet

Add new point for 

error compensation

Select all points

actual values

correct values by up&down button
confirm point correction

Mathematical correction points with big error to normal values

use gauge blocks or measuring machine for points correction

MICS

 SYSTEM FUNCTIONS

Summary of Contents for 110180027

Page 1: ...RON COMPUTERIZED MICROMETER HEAD USER MANUAL ISO 9001 2015 ISO17025 2017 USB HID LINEAR CORRECTION TIMER LIMITS TEMP COMPENSATION ISO 17025 calibration TOUCHSREEN LI POL BATTERY MAGNETIC CHARGER AX2 B...

Page 2: ...ll be saved also after switch off micrometer For zero setting press the ZERO button on Touchscreen SPECIFICATION Parameters LED display color 1 54 inch Resolution 240x240 Indication system MICS 3 0 Po...

Page 3: ...Wireless to MICROTECH Software Windows Android iOS FORMULA MODE In Formula mode we use Ax2 Bx C Main using of this function is Preset function Magnification of measured value For customers request Fo...

Page 4: ...n Wireless data transmition Activating multifunctional button to save value to memory or send data by touchscreeb ur button push Activate WIRELESS data transfer in WIRELESS menu Connect instrument wit...

Page 5: ...MATS SAVING DATA TO XLS CSV FORMATS SAVING GRAPH VOICE MODE iOS DATA TRANSFER DISTANCE FOR INTELLIGENT INSTRUMENTS All MICROTECH Intelligent instruments has internal memory You can collect data to mem...

Page 6: ...orrection RESOLUTION selected up to 0 0001mm WIRELESS modes of data transmition USB USB connection configuration DEVICE SETTING pin reset SOFTWARE link to download app MEMORY SETTING CALIBRATION DATE...

Page 7: ...o disactivate mode MENU SETTING Standard measuring A 0 B 1 C 0 PRESET 50mm A 0 B 1 C 50 Value magnification x3 A 0 B 3 C 0 Square value A 1 B 0 C 0 NoGo Go MAX value MIN value zero values MAX MIN Colo...

Page 8: ...m inch conversion Re calculation detail size to calibration conditions 20 C Manual Temperature setting 7 types of material for selection 7 types of material glass quartz solid alloys granite graphite...

Page 9: ...ng multifunctional button to save value to memory or send data by touchscreeb ur button push Activating or disactivating wireless data transfer Display rotation 0 90 180 270 Brightness level Activatin...

Page 10: ...bout device device name firmware version MAC adress for easy connection QR Link to MICROTECH web site page with MDS Software download Android iOS Windows versions Free and Pro versions Manuals Standar...

Page 11: ...MICROTECH DIMESIONAL DRAWINGS Dimensions for 25mm range...

Page 12: ...MICROTECH Change without prior notice MICROTECH innovative measuring instruments 61001 Kharkiv Ukraine str Rustaveli 39 tel 38 057 739 03 50 www microtech ua tool microtech ua...

Reviews: