6.3 Connecting the equipment 

 

1.

 

Plug  the  XLR-5F  connector  of  the 
microphone  cable  into  the  XLR-5M 
connector  of  the  microphone  until  the 
connector  clicks  audibly  into  place. 
  

2.

 

Plug  the  XLR-5M  connector  at  the  other 
end of the microphone cable into the XLR-
5F  input  connector  of  the  N  975  power 
supply until it clicks audibly into place. 

4.

 

Plug  the  XLR-3F  connector  of  the 
connection  cable  into  the  XLR-3M  output 
connector of the N 975 power supply until it 
clicks audibly into place. Plug the XLR-3M 
connector  at  the  other  end  of  the 
connection  cable  into  the  XLR-3F  input 
connector  of  the  downstream  equipment 
(eg: mixer, recorder, amplifier, etc.) until it 
clicks  audibly  into  place.                               

.

 

 

5.

 

Only  after  the  above  connections  have 
been  made,  connect  the  power  cable  into 
the IEC mains connector of the N 975 and 
then into the mains power socket (switch on 
the power at this socket if it is a switched 
socket).  
 

6.

 

Switch on the N 975 power supply with the 
on/off power switch.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6.4 Aligning the microphone 

 

Behind  the  mesh  of  the  PEM  975  is  a  green 
indicator LED.  

1.

 

Turn  on  the  LED  with  the  switch  on  the 
PEM 975 microphone.                          

.

 

  

2.

 

This  gives  the  speaker  an  indication  that 
they are in the correct pick-up area of the 
PEM  975  microphone                                           

.

 

  

3.

 

Turn  off  the  LED  (optionally,  it  can  be  left 
on  if  people  to  be  recorded  wish  to  be 
assured that they are in the pick-up area).  

The microphone is now ready for use.  

NB: When setting up, it is useful to be aware of the 
microphone’s polar-pattern. 

Care taken in setting up will give the best results.  

 

The light on the power switch lights up when the 
power supply unit is powered up.   

 

The  N  975  power  supply  unit  and  the  PEM  975 
can warm up to approx. 35º C, this corresponds 
to the normal operating temperature. 

 

The  device  can  be  damaged  or  destroyed  if 
connected  to  the  incorrect  mains  voltage.  
Therefore,  please  make  sure  that  the  N  975 
power supply is set to the correct voltage for the 
country of use (see section 7.1: Setting the supply 
voltage). 

 

If the amplification is set too high, there is the risk 
that  the  following  equipment  connected  to  the 
N  975  power  supply  unit  will  be  destroyed. 
Therefore  always  set  the  rotary  GAIN  control  to 
-36dB, before switching on the N 975. 
 

 

It is important that the cables are installed safely 
and are not twisted nor crushed; also, they should 
be  protected  from  being  pulled  or  stretched  if 
attached to moving parts. 

 

 

M.EN PEM2020.01

13

Summary of Contents for 2111142

Page 1: ...on of the KEM 975 turned 90º to be used horizontally on a lectern or table This Data Sheet is the technical specifications of the PEM 975 for more information please also see the full Data Sheet on the KEM 975 Cardioid Plane Microphone with non rotational symmetrical directivity User Manual ...

Page 2: ...rotech Gefell GmbH Georg Neumann Platz 07926 Gefell Germany Telephone 49 0 36649 882 0 Fax 49 0 36649 882 11 Internet www microtechgefell de E Mail info microtechgefell de 2 M EN 201180 01 Address M EN PEM2020 01 ...

Page 3: ...LED indicator XLR 5M connector inside PEM 975 M EN PEM2020 01 ...

Page 4: ...Rackmount kit front panel connector housing rack adapter rack adapter 4 M EN 201180 01 rack adaptor ear joining connector blank panel rack adaptor ear M EN PEM2020 01 ...

Page 5: ...11 6 2 Installing the rack 11 6 2 1 Installing the N 975 into a half 19 Rack 12 6 2 2 Installing the 19 Rack 12 6 3 Connecting the equipment 13 6 4 Aligning the microphone 13 6 5 Disassembling and storing the microphone 14 6 5 1 Storage at the venue 14 6 5 2 Storage in the transport case 14 7 Individual settings 14 7 1 Setting the supply voltage 14 7 2 Setting the level ranges 15 7 3 Setting groun...

Page 6: ...10 M EN 201180 01 6 M EN PEM2020 01 2111142 satin nickel 2111143 dark bronze ...

Page 7: ...4 dB Gain 0 dB 116 dB Gain 12 dB 128 dB Gain 24 dB 140 dB Gain 36 dB 152 dB Connecting plugs Neutrik XLR5M Weight 1 07 kg Length 343 mm Diameter Mesh 38 mm Gain 25 mm Finish nickel matt dunkel bronze Power supply N 975 Power supply voltage 230 115 V AC 10 50 60 Hz Connecting plugs KEM 975 XLR5F Audiosignal XLR3M Weight 1 6 kg Width 221 mm Depth 170 mm Height 45 mm M EN 201180 01 7 Polar pattern Ou...

Page 8: ...on We also rec ommend to inspect the device for residual dust at appropriate intervals and to have the Microtech Gefell GmbH examine it if necessary 8 M EN 201180 01 IEC mains cable Thread adaptor male to female 8mm Allen key for MH 975 Transit case 450 x 160 x 365 mm Prior to each use of the microphone make sure that all parts are in perfect condition We also recommend that the microphone is insp...

Page 9: ...the microphone make sure that all the parts are in a perfect condition We also recommend to inspect the device for residual dust at appropriate intervals and to have the Microtech Gefell GmbH examine it if necessary M EN 201180 01 9 Microphone connection cable with rt angled plug 10m satin nickel dark bronze Anti vibration mount for permanent fixing 10cm Thread adaptor to M10 Anti vibration mount ...

Page 10: ...e front of the microphone It is not a rotationally symmetric polar pattern but a cardioid pattern at rt angles to the microphone and a narrow 30 angle in the other direction The microphone is designed to capture a person speaking at a lectern podium table etc Because of the cardioid characteristic in the vertical plane it does not matter if the person is tall or short or standing up or sitting dow...

Page 11: ... can be mounted side by side in a standard rack with the supplied rack ears If a single N 975 needs to be mounted in a standard 19 rack use the supplied blanking panel in the place of the second N 975 Place the microphone and the power supply unit in such a way that they are protected from being trodden on or falling down Ensure that the cables are not strained through tension Do not use the micro...

Page 12: ...lick into place and screw it tight if mounting two N 975 together substitute the second N 975 in place of the blank panel after removing the left and right screws as described in 1 above 4 Place the joining connector on the other end of the blank panel or second N 975 and screw it tight 5 Place the pre assembled blank panel or second N 975 with the joining connector to the desired side of the N 97...

Page 13: ...ch on the PEM 975 microphone 2 This gives the speaker an indication that they are in the correct pick up area of the PEM 975 microphone 3 Turn off the LED optionally it can be left on if people to be recorded wish to be assured that they are in the pick up area The microphone is now ready for use NB When setting up it is useful to be aware of the microphone s polar pattern Care taken in setting up...

Page 14: ...ndividual settings 7 1 Setting the supply voltage The N 975 is delivered as standard set for a mains supply voltage of 230V The operating voltage can be seen by looking at the small window in the fuse module The voltage setting will need to be changed if your country uses a different supply voltage The voltage change switch is part of the fuse holder next to the IEC mains connector on the back of ...

Page 15: ...N 975 and the following devices 1 Slide the earth lift switch OUTPUT PIN 1 on the back of the N 975 to the FLOAT position This disconnects pin 1 of the XLR 3M OUTPUT connector from system ground 8 Use of accessories The PEM 975 is a self contained microphone the only accessory we would recommend is the use of a vibration absorbing mat underneath the microphone to minimise any noise transmitted to ...

Page 16: ...t has been checked and serviced by Microtech Gefell s Service Department before re sale In each case starting from the date of invoice to the end user The Guarantee excludes any defects or damage caused by negligent or improper treatment or incorrect installation or non compliance with the specifications given by Microtech Gefell GmbH or the technical specifications specified on the relevant data ...

Page 17: ...sed of with normal household waste At the end of its life cycle it should be bought to a recycling point for the recycling of electrical and electronic devices For more information please contact yout municipal authority or local government This is an important contribution to recycling EU directive 2002 96 EC M EN 201180 01 21 M EN PEM2020 01 17 ...

Page 18: ...icrotech Gefell GmbH Georg Neumann Platz 07926 Gefell Germany Phone 49 0 36649 882 0 Fax 49 0 36649 882 11 www microtechgefell de info microtechgefell de M DE 201180 01 31 08 2016 c Microtech Gefell GmbH ...