background image

Figure 7

. Control of circulation pump and electric heater. Hyst, Hyst 2, HeatSP and

DeltaSP parameters

SET button using and parameter adjustment: 

1. Entering the 

heater set point - HeatSP

 – hold 

SET

 button for 

2 sec

. and release. A

HeatSP 

message has appear and the option to change it with the

 Up 

and

 Down 

buttons

 .

Confirms with

 SET.

2. 

Setting the system parameters – hold SET

 button 

for 5 sec.

 until a message appears

Enter in tune. SET 

is used to confirm and move to the next parameter. Change with the

Up and Down 

buttons.

3. 

Setting all (secret and system) parameters–  like  above, but with SET pressed

when power is applied

After   passing   through   all   parameters,   the   main   menu   is   activated   again.   This   also

happens if no action is taken during the setting for 15 seconds

6. SYSTEM PARAMETERS

Parameters

Factory

setting

Allowable

value

Meaning

"DeltaSP"

5

 100 °C

Auto Mode Pump set point (Figure 7)

"AlarmTb"

85

 100 °C

Tb

 alarm in automatic mode

"AlarmTo"

80

 100 °C

To

 alarm in automatic mode

"Hyst "

3

 10 °C

Pump control hysteresis (Fig. 7)

“minTs”

40

-50

100  °C Minimum exchange temperature (see pump 

control rules)

"HystTs "

1

 10 °C

Hysteresis to “minTs”

"Hyst 2"

1

 10 °C

Heater control Hysteresis 

"HeatSP"

45

 AlarmTb–

Hist2

Heater  set point  (independent    of mode). The
range   is   automatically   respected   when
changing to 

AlarmTb–Hist2

Document  edition 

2020-04-22

6

Delta

SP

Hyst

Hyst

Pump

Ts-To

Heat

SP

Hyst2 Hyst2

Heat

To

ON

OFF

ON

OFF

Summary of Contents for SR 03

Page 1: ...COMPETENCE IN MEASUREMENT SOLAR AND HEATING SYSTEMS TEMPERATURE CONTROLLER SR 03 TECHNICAL DESCRIPTION AND USER MANUAL PLOVDIV 2020 Document edition 2020 04 22...

Page 2: ...imensions WxHxL Wall Mounting Housing 125 85 58 mm DIN rail M36 70x86x57 Box Material Wall Mounting Housing MS C4 Plastic DIN rail M36 Noryl VO1550 black base Lexan 940 gray upper Weight max 450 g Lev...

Page 3: ...2 Front panel of device in wall mount housing 3 TERMINALS AND CONNECTIONS Figure 3 Connection of device in wall mount housing Document edition 2020 04 22 3 Pt 1000 Input Ts Tb To 220V Fuse K1 K2 Solar...

Page 4: ...depending of differences in temperature at measuring points The heater is controlled by temperature set point independently of the pump mode Tb To Ts Pump Heater Tb temperature sensor is placed on the...

Page 5: ...t MODE is use for modes switch The three modes are as follows AUTO automatic pump control ON absolutely pump switch on OFF absolutely pump switch off Pump control rules by priority in AUTO mode Condit...

Page 6: ...s applied After passing through all parameters the main menu is activated again This also happens if no action is taken during the setting for 15 seconds 6 SYSTEM PARAMETERS Parameters Factory setting...

Page 7: ...action area 3 T Jump 3 10 0 255 0 2 s Time of perception of measurement outside Jump 3 Alarm s 90 0 250 C Ts alarm pipeline overheating in automatic mode see pump control rules AlarmFr 4 50 50 C Insta...

Page 8: ...rt bad conservation wrong exploitation naturedisasters not following the instructions and the cases when there is an attempt to fix anydefects by other people In those cases the issue is being fixed o...

Reviews: