3.5 Configuring the Ethernet Interface
The Ethernet interface must be configured before use (IP address, net
mask and port number settings):
Advice for Windows 7 users:
The Telnet client must be activated:
Start -> Control Panel -> Programs -> Turn Windows features on or off
-> Telnet Client
Switch the display unit on and connect it to the network hub with an
RJ45 cable (1:1 cable) or directly to a PC (crosslink cable).
Start the “MS DOS entry prompt” at your Windows PC.
With Windows 7 you must have extended rights:
Start -> All Programs -> Accessories -> double-click at Command Promp
-> Run as Administrator
Enter the desired IP address for the display unit to the ARP table:
ARP -S XXX.XXX.XXX.XXX xx-xx-xx-xx-xx-xx < CR>
XXX.XXX.XXX.XXX : desired IP address
xx-xx-xx-xx-xx-xx
: display unit’s Ethernet address
(see label next to the RJ45 socket)
Establish a Telnet connection to port 1:
TELNET XXX.XXX.XXX.XXX 1 < CR>
This connection will fail (disconnect within 3 seconds). However, the
display unit’s IP address is temporarily changed.
Close the Telnet window after acknowledging the error message.
Establish a Telnet connection to port 9999:
TELNET XXX.XXX.XXX.XXX 9999 < CR>
After the connection has been established, immediately press the
enter key (within 5 seconds) in order to enter the setup mode.
Please do never
select item “7” (Defaults). These settings do not
match to the display.
In case of an error you can find the factory settings in chapter
“Factory Settings of internal Interface”.
Enter “0” (server configuration).
Enter the desired IP address and press the enter key.