4.6.6 Voltage Rail Monitoring
The carrier monitors all voltage rails and resets the module in case any voltage
drops below
it’s
undervoltage limit:
Voltage
Monitoring
Threshold (nom.)
12V
Undervoltage
10.8V
5V
Undervoltage
4.5V
3.3V
Undervoltage
3.08V
2.5V
Undervoltage
2.25V
1.8V
Undervoltage
1.62V
1.5V
Undervoltage
1.35V
1.3V
Undervoltage
1.17V
1.1V
Undervoltage
0.99V
0.88V
Undervoltage
0.79V
Table 4-5 Voltage monitoring limits (carrier)
4.6.7 Fuses
The fuse F1 (ASMDC185F/33, 33V max, 1,85 A trip) protects the general purpose
PLC output driver stage for connector ST43.