background image

Technical data

blind zone

operating range
maximum range

angle of beam spread

0 to 350 mm 
3,400 mm

0 to 600 mm 
6,000 mm

5,000 mm
see »detection zones«

8,000 mm
see »detection zones«

transducer frequency

resolution

reproducibility

detection zones

for different objects:

The dark grey areas represent the zone 

where it is easy to recognise the normal 

reflector (round bar). This indicates the typical 

operating range of the sensors. The light 

grey areas represent the zone where a 

good reflector – for instance a 

plate – can still be regognised. The 

requirement here is for an optimum 

alignment to the sensor. It is not 

possible to evaluate ultrasonic 

reflections outside this area. 

ca. 120 kHz
0.18 mm

ca. 80 kHz
0.18 mm

± 0.15 %

± 0.15 %

accuracy

operating voltage U

B

±1 % (temperature drift internally compensated; may
be deactivated, 0.17 %/K without compensation)

±1 % (temperature drift internally compensated; may
be deactivated, 0.17 %/K without compensation)

9 V to 30 V DC, Class 2
reverse polarity protection

9 V to 30 V DC, Class 2
reverse polarity protection

voltage ripple

no-load current consumption

housing

±10 %

  60 mA

±10 %

  60 mA

PBT, Polyester; ultrasonic transducer:
polyurethane foam, epoxy resin with glass content

PBT, Polyester; ultrasonic transducer:
polyurethane foam, epoxy resin with glass content

class of protection per EN 60 529

type of connection 

controls

programmable

IP 67
5-pin M12 circular plug, PBT

IP 67
5-pin M12 circular plug,. PBT

2 push-buttons
• Teach-in via push-buttons

2 push-buttons
• Teach-in via push-buttons

 indicators

synchronisation

operating temperature

• LCA-2 with LinkControl
2 LEDs yellow/green (switched output set/not set)

• LCA-2 with LinkControl
2 LEDs yellow/green (switched output set/not set)

internal synchronisation up to 10 sensors
-25°C to +70°C

internal synchronisation up to 10 sensors
-25°C to +70°C

storage temperature

weight

switching hysteresis 

1)

switching frequency 

1)

-40°C to +85°C
180 g

-40°C to +85°C
240 g

50 mm
4 Hz

100 mm
3 Hz

response time 

1)

time delay before availability 

1)

norm conformity

172 ms
< 380 ms

240 ms
< 450 ms

EN 60947-5-2

EN 60947-5-2

order no.

switched output

1) Can be programmed with LinkControl

lcs+340/DD

2 x pnp, U

B

-2 V, I

max

 = 2 x 200 mA

lcs+600/DD

2 x pnp, U

B

-2 V, I

max

 = 2 x 200 mA

NOC/NCC adjustable, short-circuit-proof

NOC/NCC adjustable, short-circuit-proof

+U

B

-U

B

D1
D2
Sync/Com

1
2
4
5
3

2 pnp switched outputs

U

lcs+340…

lcs+600…

0 m

0.8 m

1.6 m

2.4 m

3.2 m

4 m

4.8 m

5.6 m

3.4 m

Plate

Round bar ø 27 mm

1.6 m

0.8 m

0 m

0.8 m

1.6 m

0 m

1.2 m

2.4 m

3.6 m

4.8 m

6 m

7.2 m

8.4 m

Plate

Round bar ø 27 mm

2.4 m

1.2 m

0 m

1.2 m

2.4 m

*B10634*

MV-DO-121024-464442

microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany / 

T

 +49 231 975151-0 / 

F

 +49 231 975151-51 / 

E

 [email protected]

W

 microsonic.de     The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not confirm any product features.

2004/108/EC

Enclosure Type 1

For use only in industrial 

machinery NFPA 79 applications.

In the »Two-way reflective barrier«
operating mode, the object has to
be within the range of 0-85 % of
the set distance.

In the Teach-in procedure »Set de-
tect point – method A« the actual
distance to the object is taught to
the sensor as the detect point. If
the object moves towards the
sensor (e.g. with level control) then
the taught distance is the level at
which the sensor has to switch the
output.

If the object to be scanned moves
into the detection area from the
side, the Teach-in procedure »Set
detect point +8 % – method B«
should be used. In this way the
switching distance is set 8 % fur-
ther than the actual measured dis-
tance to the object. This ensures a
reliable switching distance even if
the height of the objects varies
slightly.

 

Fig. 3: Setting the detect point for different  

directions of movement of the object

The sensor can be reset to its fac-
tory setting (see »Sensor adjust-
ment with Teach-in procedure«).

Optionally all Teach-in and addi-
tional sensor parameter settings
can be made using the LinkCon-
trol adapter (optional accessory)
and the LinkControl software for
windows.

Enclosure Type 1

For use only in industrial 

machinery NFPA 79 applications.

Reviews: