Technical data
blind zone
operating range
maximum range
angle of beam spread
0 to 350 mm
3,400 mm
0 to 600 mm
6,000 mm
5,000 mm
see »detection zones«
8,000 mm
see »detection zones«
transducer frequency
resolution
reproducibility
detection zones
for different objects:
The dark grey areas represent the zone
where it is easy to recognise the normal
reflector (round bar). This indicates the typical
operating range of the sensors. The light
grey areas represent the zone where a
good reflector – for instance a
plate – can still be regognised. The
requirement here is for an optimum
alignment to the sensor. It is not
possible to evaluate ultrasonic
reflections outside this area.
ca. 120 kHz
0.18 mm
ca. 80 kHz
0.18 mm
± 0.15 %
± 0.15 %
accuracy
operating voltage U
B
±1 % (temperature drift internally compensated; may
be deactivated, 0.17 %/K without compensation)
±1 % (temperature drift internally compensated; may
be deactivated, 0.17 %/K without compensation)
9 V to 30 V DC, Class 2
reverse polarity protection
9 V to 30 V DC, Class 2
reverse polarity protection
voltage ripple
no-load current consumption
housing
±10 %
≤
60 mA
±10 %
≤
60 mA
PBT, Polyester; ultrasonic transducer:
polyurethane foam, epoxy resin with glass content
PBT, Polyester; ultrasonic transducer:
polyurethane foam, epoxy resin with glass content
class of protection per EN 60 529
type of connection
controls
programmable
IP 67
5-pin M12 circular plug, PBT
IP 67
5-pin M12 circular plug,. PBT
2 push-buttons
• Teach-in via push-buttons
2 push-buttons
• Teach-in via push-buttons
indicators
synchronisation
operating temperature
• LCA-2 with LinkControl
2 LEDs yellow/green (switched output set/not set)
• LCA-2 with LinkControl
2 LEDs yellow/green (switched output set/not set)
internal synchronisation up to 10 sensors
-25°C to +70°C
internal synchronisation up to 10 sensors
-25°C to +70°C
storage temperature
weight
switching hysteresis
1)
switching frequency
1)
-40°C to +85°C
180 g
-40°C to +85°C
240 g
50 mm
4 Hz
100 mm
3 Hz
response time
1)
time delay before availability
1)
norm conformity
172 ms
< 380 ms
240 ms
< 450 ms
EN 60947-5-2
EN 60947-5-2
order no.
switched output
1) Can be programmed with LinkControl
lcs+340/DD
2 x pnp, U
B
-2 V, I
max
= 2 x 200 mA
lcs+600/DD
2 x pnp, U
B
-2 V, I
max
= 2 x 200 mA
NOC/NCC adjustable, short-circuit-proof
NOC/NCC adjustable, short-circuit-proof
+U
B
-U
B
D1
D2
Sync/Com
1
2
4
5
3
2 pnp switched outputs
U
lcs+340…
lcs+600…
0 m
0.8 m
1.6 m
2.4 m
3.2 m
4 m
4.8 m
5.6 m
3.4 m
Plate
Round bar ø 27 mm
1.6 m
0.8 m
0 m
0.8 m
1.6 m
0 m
1.2 m
2.4 m
3.6 m
4.8 m
6 m
7.2 m
8.4 m
Plate
Round bar ø 27 mm
2.4 m
1.2 m
0 m
1.2 m
2.4 m
*B10634*
MV-DO-121024-464442
microsonic GmbH / Phoenixseestraße 7 / 44263 Dortmund / Germany /
T
+49 231 975151-0 /
F
+49 231 975151-51 /
E
W
microsonic.de The content of this document is subject to technical changes. Specifications in this document are presented in a descriptive way only. They do not confirm any product features.
2004/108/EC
Enclosure Type 1
For use only in industrial
machinery NFPA 79 applications.
In the »Two-way reflective barrier«
operating mode, the object has to
be within the range of 0-85 % of
the set distance.
In the Teach-in procedure »Set de-
tect point – method A« the actual
distance to the object is taught to
the sensor as the detect point. If
the object moves towards the
sensor (e.g. with level control) then
the taught distance is the level at
which the sensor has to switch the
output.
If the object to be scanned moves
into the detection area from the
side, the Teach-in procedure »Set
detect point +8 % – method B«
should be used. In this way the
switching distance is set 8 % fur-
ther than the actual measured dis-
tance to the object. This ensures a
reliable switching distance even if
the height of the objects varies
slightly.
Fig. 3: Setting the detect point for different
directions of movement of the object
The sensor can be reset to its fac-
tory setting (see »Sensor adjust-
ment with Teach-in procedure«).
Optionally all Teach-in and addi-
tional sensor parameter settings
can be made using the LinkCon-
trol adapter (optional accessory)
and the LinkControl software for
windows.
Enclosure Type 1
For use only in industrial
machinery NFPA 79 applications.