background image

 

5) The protection of transmitter is IP65

 

6) Prevent leak, friction and temperature difference error, to prevent 

dregs settling on the tube affecting the diaphragm. 

7) The transmitter has been calibrated when out of the factory, the 

customer  can  operate  the  transmitter  without  calibration,  but 
checking the installation and electrical connection correct or not is 
necessary.  The  transmitter  can  work  when  excitation  is 
connected, but the signal output is more reliable after 30 minutes. 

8) Ban to pulling the cable violently, and to prevent the diaphragm 

damaging don’t poke the diaphragm with metal still objects. 
MDM4901FL  piezo-resistive  differential  pressure  transmitter 
allows the customers to adjust the zero and Span output signals 
while you own a standard pressure controller. While adjusting, for 
the  transmitter  with  plug connection,  remove  the socket on the 
top of housing (take care not to break the cable), then trim “Zero” 
and  “Span”  buttons  to  adjust.  For  the  transmitter  with  cable 
connection, you need to use a wrench slightly screw the cap and 
you will find the Zero and Span calibrators on the top of housing. 
Restore them when finish. 

If the transmitter is fail to work, the customer should contact with 
factory checking the reasons, and return to factory for repair. 
Caution

do not poke the pressure-leading hole with metal wire or 

something hard; and do not pres 

4 Electric Connection 

4.1 The  transmitter  is  connected  with  the  outside  circuit 

Summary of Contents for MDM4901FL

Page 1: ...MDM4901FL Operation Manual...

Page 2: ...tion manual due to renovation of production technology and craftwork If some information is changed no more notice will be edited Please pay attention to the latest version Our company also reserves t...

Page 3: ...2 wire 4mA 20mADC and 3 wire 0 1V 5VDC 0mA 10mA 20mADC signal output by external power supply 24VDC as well zero and span compensation in the wide temperature range The parts being contacted with the...

Page 4: ...l PE PVC 20 80 cable material PUR Storage Temperature 40 120 20 85 Cable Response 1ms Insulation 100M 50VDC Housing Protection IP65 3 Outline Construction and Installation Unit mm 3 1 Construction and...

Page 5: ...in the worksite is no more than the maximum pressure c For positive and negative pressure balance and convenient repair we recommend to use tri valve such as J23SA to connect with the leading tube to...

Page 6: ...her the measured medium is consistent with the transmitter structure material 3 Pay attention to the measuring medium is compatible with the construction material or not Notice the positive and negati...

Page 7: ...resistive differential pressure transmitter allows the customers to adjust the zero and Span output signals while you own a standard pressure controller While adjusting for the transmitter with plug...

Page 8: ...tric definitions of cable are as follow Table 2 Cable 2 wire 3 wire Red V V Black OV OUT GND White Null OUT The electric definitions of M12x1 Plug are as follow Table 3 Fig 6 4 2 Electrical connection...

Page 9: ...DC current U 0 1V 5V GND Fig 8 4 3 Plug connection Operation Method a If the plug has been connected with transmitter loose the central bolt on the top of plug with little screwdriver and pull out th...

Page 10: ...cable slightly and push the plug core into housing a rattling sound could be listened then screw down the cable fixed nut e To remove the cable loose the cable fixed nut to relax the cable and operate...

Page 11: ...on order Product operation menu 1pc Product certificate of quality 1pc Quality following card 1pc 5 3 Storage The transmitter should be stored in dry ventilate room ambient temperature 40 120 20 85 Ca...

Page 12: ......