  Technical specifications 

Type

 

Manageable Fast Ethernet switch with 4 x 10/100Base-TX and  
2 x 100Base-FX uplink for industrial fiber ring 

Fiber type

 

Multimode 62,5/125 or 50/125µm, 
Single mode 9/125µm, duplex 

Cable type

 

Shielded Twisted Pair cable, 100 Ohm, Category 5,  
Pinout RJ45-ports auto crossing 

Data rate 

10 or 100 Mbit/s 

LED displays

 

Power   

Ready for operation 

Link 

 

Link status each port 

Act 

 

Data traffic each port 

FDX/HDX 

Half or full duplex transmission each port 

Alarm   

Fiber link interrupted 

Mounting 

35 mm hat rail, according DIN EN 50 022 

Power supply 

18 - 36 V DC / max. 250 mA by external power supply  
connections with screw terminals, redundant ports 

Dimensions 

38 x 108 x 116 mm (w x d x h) 

Operating temperature 

-20°C to 60°C 

Storage temperature 

-20°C to 80°C 

Rel. humidity 

5% to 90% non condensing 

Management 

- Status information via web based management (http-Server) or 
   support of SNMPv1  
- Configuration via PC based management tool (Device Manager)

  

 

  Optical parameter 

Multimode 

min. distance: 

2 km (full duplex) 

Output power: -19 

dBm 

Sensitivity: 

-31 dBm  

Wavelength: 

1300 nm 

Single mode 

min. distance: 

15 km (full duplex) 

Output power: 

- 15 dBm 

Sensitivity: 

- 31 dBm  

Wavelength: 

1300 nm 

 

  Mounting 

The switch is housed in a solid metal box with an integrated fixture for the installation on 
standard 35 mm DIN EN 50 022 rails.  

The fixation of  the MICROSENS switch on the rail is done with a locking pin that can be opened 
from the bottom side. If multiple devices are mounted in line, a minimum space of 20 mm should 
be kept between the devices, to ensure a sufficient heat dissipation.

 

 

MICROSENS

 GmbH & Co. KG - Kueferstraße 16 - 59067 Hamm / Germany - Tel. +49 23 81/94 52-0 - FAX -100 - www.microsens.com

 

Summary of Contents for MS650501M

Page 1: ...b based using an integrated HTTP server In addition to the two 100Base FX fiber connections for chain linking several industrial switches the MICROSENS industrial switches also offer four 10 100Base TX connections for linking such Ethernet terminals as machine controls network uplinks consoles and other network participants For particularly demanding uses the industrial switches are designed in a ...

Page 2: ...ing temperature 20 C to 60 C Storage temperature 20 C to 80 C Rel humidity 5 to 90 non condensing Management Status information via web based management http Server or support of SNMPv1 Configuration via PC based management tool Device Manager Optical parameter Multimode min distance 2 km full duplex Output power 19 dBm Sensitivity 31 dBm Wavelength 1300 nm Single mode min distance 15 km full dupl...

Page 3: ...to crossing function of all Twisted Pair ports makes the use of crossed patch cables unnecessary The switch automatically detects the pinout of the connected cable and adapts the port accordingly For all connections standard 1 1 Twisted Pair cables can be used The Autonegotiation mechanism detects automatically the speed and transmission mode full or half duplex between connected ports A manual co...

Page 4: ...this tool it is also possible to do the initial TCP IP setting IP address Gateway etc This configuration can be changed afterwards using the TCP IP protocol Attention The description for the initial settings can be found in the online manual The management information are available inside of the network inband management A special connection is not necessary Due to this all four twisted pair ports...

Page 5: ...ing connection is logically interrupted by monitoring device switch configured for Ring Master mode In case of failure broken connection or switch damage the logically interrupted connection is activated by Ring Master A big advantage of this solution is that no additional central device is necessary for the redundancy feature Even if the ring master itself fails the interruption of the ring stays...

Page 6: ...h is having the manager function all other switches are normal ring switches Each switch is monitoring the status of the connected fiber segment In case of failure the connected switch forwards this information to the ring manager The ring manager terminates the interruption of the ring immediately The data is transmitted in all directions then This fast signaling a fast failure detection within a...

Page 7: ...r keeps the operation of the complete segment up Advantage of this solution is that the ring manager itself has not to be redundant because if the manager fails the data can not be multiplied The segments stays under operation To avoid that the signaling in case of failure has no affect on other rings it is possible to define different rings with numbers from 0 to 255 by the network management All...

Page 8: ...The duplex settings are independent from the mode of the ring feature Safety Notes WARNING Infrared radiation as used for data transmission within the fiber optic although invisible to the human eye can nevertheless cause damage To avoid damage to the eyes never look straight into the output of fiber optic components danger of blinding cover all unused optical connections with caps commission the ...

Page 9: ...MS650505M Fast Ethernet Switch with ring function 4x 10 100Base TX 2x 100Base FX ST single mode 1310 nm 4x ST 4x RJ45 2x power input MS650506M Fast Ethernet Switch with ring function 4x 10 100Base TX 2x 100Base FX SC single mode 1310 nm 2x 40 km 2x SC duplex 4x RJ45 2x power input MS650507M Fast Ethernet Switch with ring function 4x 10 100Base TX 2x 100Base FX ST single mode 1310 nm 2x 40 km 2x ST...

Page 10: ... 85 264 VAC In 3 pin Out 5 pin MS700422 Hat rail power supply 120 Watt 24 V 5 0 A wide range input 85 264 VAC In 3 pin Out 5 pin MS700430 Hat rail power supply 60 Watt 48 V 1 25 A wide range input 85 264 VAC In 3 pin Out 5 pin MICROSENS reserves the right to make any changes without further notice to any product to improve reliability function or design MICROSENS does not assume any liability aris...

Reviews: