2.4
Power Cord Specifications by Country
U.S.A. and
Canada
Cord must be UL-approved or CSA certified.
Minimum specification for flexible cord is:
o
No. 18 AWG
o
Type SV or SJ
o
Three-conductor
Cord set must have a rated current capacity
of at least 13A for, 9024G/ACDC/M/F, and
PD-9024G/AC/F; and 10A for PD-
9024G/ACDC/M, PD-9024G/AC,
PD-9012G/ACDC/M
,
,
PD-9012G/AC,
PD-9006G/ACDC/M
,
,
and PD-9006G/AC.
The attachment plug must be an earth-
grounding type with a NEMA 5-15P (15A,
125V) or NEMA 6-15P (15A, 250V)
configuration.
Denmark
Supply plug must comply with section 107-2-D1, standard
DK2-1a or DK2-5a.
Switzerland
Supply plug must comply with SEV/ASE 1011.
France and
Peru
IT supplies cannot power this unit. If your supplies are an
IT type, unit must be powered by 230V (2P+T) via an
isolation transformer with a 1:1 ratio, and with secondary
connection point labeled Neutral and connected directly to
ground.
U.K
Power over Ethernet Midspan is covered by General
Approval NS/G/12345/J/100003, for indirect connection to
a public telecommunications system.