PD-IM-7648 Evaluation System - User Guide
Copyright © 2013
Microsemi
16
Rev 1.0 / 25 Dec 13
Analog Mixed Signal Group
1 Enterprise, Aliso Viejo, CA 92656, USA; Phone (USA): (800) 713-4113, (ROW): (949) 221-7100 Fax: (949) 756-0308
This interface supplies 'Power Good' indication signals coming from power supplies, indicating operating/failed
power supply status and a hot-swap signal for a hot-swappable PoE application.
MB: J1
Pin No.
Signal Name
Description
1
PG0
'Power good' signal – power supply status indication.
2
PG1
'Power good' signal – power supply status indication.
3
PG2
'Power good' signal – power supply status indication.
4
PG3
'Power good' signal – power supply status indication.
5
GND_D
Digital ground at PoE domain.
6
xHSWP
Hot Swap control signal, indicating PoE application is hot swappable.
Manufacturer: CviLux
Manufacture part number: CI25-06P1V00
Figure 17: External Power Supplies