Copyright
2017
Microsemi
Page 4
PD-9501GO-ET
One Enterprise Aliso Viejo, CA 92656 USA
Dust & Water protection
o
IEC60529, level IP67
o
NEMA 250, level 4x
Note
Do not use cross-over cable between the PoE Midspan output
port and load device.
WARNING
Take extra care when connecting the AC power inlet terminals, so
that 'N', 'L' and 'Ground' are connected to the proper polarity.
Ensure the AC power is within the allowed range.
Mounting Instructions Installation
Note:
Before mounting the PoE Midspan to a fixed location:
To insure weather-proof connection in order to meet IEC60529
level IP67. PoE Midspan AC power plug needs to be connected to
a weather-proof AC power source box.
There is no “On-Off” switch; simply plug the PoE Midspan into an
AC main power source.
PoE Midspan AC power lines should be connected to the socket-
outlet that shall be installed near the equipment and be easily
accessible.