Chapter A
A-4
MS-810 Industrial Scanner User’s Manual
A
p
p
e
ndice
s
Appendix B — Electrical Specifications
Power Supply Requirements: 10–28 VDC, 200 mV p-p max. ripple, 2.7 watts rated 24
VDC (standard); also available: +5V ±4% regulated @ 480 mA with 200 mV p-p max.
ripple.
Table A-3 10 to 28 VDC Pinouts for Standard Options
Figure A-2 15-pin High-density D-subminiature plug
Discrete I/O
Trigger Input
: Opto-isolated, 5–28V rated, (12 mA @ 24 VDC)
Outputs (1&2)
: Opto-isolated, 1–28V rated, (I CE <100 mA @ 24 VDC, current limited
by user)
Optoisolator Connection Diagrams for 10-28 Volt
With the MS-810 scanner’s optoisolator, input and output signals can be isolated from
the scanner’s internal circuitry. Please carefully observe the following schematics and
their indicated current limitations before connecting to power.
CAUTION
: The user must limit the maximum current through the optoisolator to 100 mA.
Pin #
Function
Pin #
Function
1
+10–28 VDC (in)
9
Trigger input (+)
2
RS-232 TXD/RS-422 TXD (–)
10
CTS (in)/RS-422 RXD (+)
3
RS-232 RXD/RS-422 RXD (–)
11
Output 1 (–)
4
Signal ground (RS-232)
12
New master
5
Output 2 (–)
13
Chassis ground
6
RTS (out)/RS-422 TXD (+)
14
Output 2 (+)
7
Output 1 (+)
15
Trigger input (–)
8
Default configuration (in)
1
6
11
15
5
10
Summary of Contents for MS-810
Page 1: ...MS 810 Industrial Scanner User s Manual P N 83 000810 Rev B...
Page 22: ...Chapter 1 1 12 MS 810 Industrial Scanner User s Manual 1 Quick Start...
Page 82: ...Chapter 3 3 20 MS 810 Industrial Scanner User s Manual 3 Serial Config...
Page 98: ...Chapter 4 4 16 MS 810 Industrial Scanner User s Manual 4 Utilities...
Page 138: ...Chapter A A 40 MS 810 Industrial Scanner User s Manual Appendices...
Page 144: ...I 6 MS 810 Industrial Scanner User s Manual Index Index...