background image

INTENDED USE

Micropoint Biotechnologies, Inc. has optional 

liquid controls for qLabs

®

 Vet Coag Panel 2 

system. The qLabs

®

 Vet Coag Panel 2 Liquid 

Controls are used with qLabs

®

 Vet Coag 

Panel 2 Test Strips to verify the qLabs

®

 Vet 

Coag Panel 2 system performance. It is 

recommended that two levels of liquid controls 

are used to perform the test.

WARNING AND PRECAUTIONS

1.  For in vitro diagnostics use only. Do not
    take internally. 

2.  Read the instructions carefully before using.

Deviations  from  the  described  procedure     

may alter performance. 

3.  

Take all necessary precautions required 

when handling laboratory reagents. 

4.  Do not freeze liquid controls. 

5.  Do not use expired liquid controls.

6.  Do not use for any purpose other than 

described in the “Intended Use” section. 

7.  Do not interchange caps as contamination 

may occur and compromise results. 

qLabs

®

 Vet Coag Panel 2 Liquid Control

For Health Care Professional Use Only

qLabs

®

 Vet Coag Panel 2 Liquid Control Kit Specification / Order Information

REF

Quantity

Name

Storage

QSV-1-CL Pro

2 x 1 ml

qLabs

®

 Vet Coag Panel 2 Liquid Control Level 1

(For Professional Use Only )

18-30 

o

C

2 x 1 ml

qLabs

®

 Vet Coag Panel 2 Liquid Control Level 2

(For Professional Use Only)

18-30 

o

C

Summary of Contents for qLabs QSV-1-CL Pro

Page 1: ...rocedure may alter performance 3 Take all necessary precautions required when handling laboratory reagents 4 Do not freeze liquid controls 5 Do not use expired liquid controls 6 Do not use for any purpose other than described in the Intended Use section 7 Do not interchange caps as contamination may occur and compromise results qLabs Vet Coag Panel 2 Liquid Control For Health Care Professional Use...

Page 2: ... qLabs Vet Coag Panel 2 Test Strip qLabs Vet Coag Panel 2 Liquid Control Level 1 and Level 2 Note Please refer to the user s manual for appropriate operation instructions about the test strip and the meter 2 Insert the strip Press the power button for 2 seconds to turn on the qLabs Vet Remove a new qLabs Vet Coag Panel 2 Test Strip from foil pouch Insert the strip electrode end first into the test...

Page 3: ...the strip printed on the label of the foil pouch 7 Confirm the code and lot number of the strip Press OK button to confirm the code and lot number of the strip Once the lot number of strip is entered the meter will automatically check whether the strip is expired or not If the strip is expired the user shall use another strip within the expiration period to perform the test Note Always match the s...

Page 4: ...tem is working properly and all testing procedure has been done correctly when the test results obtained fall within the assigned control PT and APTT range on the vial Note Please refer to the assigned PT and APTT control range printed on the label of the vial UNEXPECTED RESULTS If the test results fall outside of the assigned range or qLabs ElectroMeter displays error code E XXX check for the fol...

Page 5: ... 0 48 2 76 Level 2 31 97 1 12 3 49 Within Run N 20 APTT Value Mean S D CV Level 1 113 03 4 35 3 85 Level 2 144 41 4 53 3 14 Between Run N 40 APTT Value Mean S D CV Level 1 115 48 3 86 3 34 Level 2 143 80 7 03 4 89 ADDITIONAL INFORMATION For additional information about this product please call your local distributor or call our customer service at 86 755 86296766 ...

Page 6: ...Symbols Explanation In Vitro Diagnostics Name and Address of Manufacturer Temperature Limitation Lot Number Expiry Date Catalogue Number Catains Sufficient for n Tests Caution Read Carefully ...

Page 7: ...6 755 86673903 Obelis SA Bd General Wahis 53 1030 Brussels Belgium www obelis net Tel 32 2 732 59 54 Fax 32 2 732 60 03 2015 Micropoint Biotechnologies Inc All rights reserved Specifications are subject to change without notice Printed in China qLabs and Micropoint are registered trademarks of Micropoint Bioscience Inc P N 99030545431 Rev A1 ...