CAUTIONS
BEFORE USE

The electronic levels are supplied in ABS 
anti-shock boxes. 
Inside each box you can find a complete 
set of components, needed for the  proper 
operation of the level (see the component 
list for each model).

Herewith are a few suggestions for the 
maintenance and proper use of your in-
strument:

Before measuring, clean thoroughly the 
surface to be checked and the base of the 
level with s

pecific detergents

 (Paste for 

granite, Art. TZ0510 – Liquid detergent, 
Art. DT0520). Never use wax, grease or 
water-based detergents for cleaning gra-
nite.

Never use the instrument close to 

magne-

tic fields

, as the measurements could be 

altered.

The surface plate to be checked should 
be 

levelled

 as closely as possible to avoid 

inaccuracies of the readings due to com-
pound errors.

Check the levelling of the plate or the sur-
face to be measured by using a spirit level 
following the instructions supplied with 
the Microplan plates (Test report).

Before starting the measurement, check 
the 

battery charge

, pushing the button 

‘Batt’ (VA110), or just checking that the 
display does not show ‘Low Bat’ (VD110 
and LE051).

 
Check the instrument periodically, to 

 

verify its calibration and  performance. A 

periodical check

 of the instrument can 

ensure better performance and lower 
maintenance costs over time.

 

Lato Etichetta

Label Side

L

0.22 

L

0.22 

L

0.22 

W

0.22 

W

0.5 

W

0.5 

W

W

Vista Inferiore

Bottom view

Summary of Contents for LE051

Page 1: ...LE051 ELECTRONIC LEVEL USER S MANUAL your partner for metrology...

Page 2: ...2 2016 Microplan Documento LE051_IT Versione 16 04 All rights reserved Microplan 2016...

Page 3: ...m always hangs ver tically thus allowing measurement of the displacement relative to the horizontal base by means of an inductive position transducer The innovation that applies to all MICRO PLAN leve...

Page 4: ...data transmission to PC RoHS compliant Lagammecompl tedesniveaux lectroniquesMicroplan Unit de lecture num rique analogique ou analogique num rique Syst me innovant de m canique dans bain d huile pou...

Page 5: ...tic fields as the measurements could be altered The surface plate to be checked should be levelled as closely as possible to avoid inaccuracies of the readings due to com pound errors Check the level...

Page 6: ...sitivity is as high as 1 m m 0 2 second of arc The internal software manages the whole acquisition process the measures avera ging and the data display on a 16 charac ters LCD and a galvanometer for a...

Page 7: ...ccessories LE051 Art LE0433 LE051 Unit Battery charger included with unit LE0433 Art LE0435 Serial connection cable between level and PC optional Art LE0439 WPLAN Microplan Flatness Software opzional...

Page 8: ...ter untill when you reach the half of the read value Example if you read 26 m in the position a adjust the potentiome ter to 13 m on position b 3 Repeatthesamesteps 1 2 byturning the level of 90 as sh...

Page 9: ...advise customer against using other battery chargers which could damage the inner batteries of the level The battery charger state is shown on the digital display when the level is switched on with th...

Page 10: ...2 The cable connects the LE051 unit to the pc through the serial gate COM1 o COM2 and needs the use of WPLAN MICROPLAN Flatnesssoftwa re release 4 I Regarding the complete procedure for the memorized...

Page 11: ...019 VARALLO Vercelli ITALY 39 0163 54619 569084 39 0163 564081 mpi microplan group com Skype microplan italia www microplan group com TECHNICAL SUPPORT By doubt or information regarding the working of...

Page 12: ...54619 569084 FAX 39 0163 564081 EMAIL mpi microplan group com SKYPE microplan italia MICROPLAN FRANCE SAS 2 LA GRAULE F 23360 LA FORET DU TEMPLE FRANCE TEL 33 5 55806666 FAX 33 5 55806620 EMAIL mpf mi...

Reviews: