MicroNX ELEC ENGINE ISE-170L Instructions For Use Manual Download Page 5

2.1 Danger

1) When cause of abnormality is not detected or abnormality is not easily solved, 
    contact the head office immediately.
2) When the display is wrongly shown, make inquiries to the head office. It is at risk for accident.
3) Do not bring any patient into contact with signal input section or signal output section and 
    other connections.

2.2 Warning

1) Do not disassemble or make alterations to the product. Once the product is disassembled, 
    you cannot get after-sale service from the company.
2) Do not inject oil into BLDC motor. It causes bearing breakdown and heat.
3) Do not clean the product using a solvent such as thinner, benzene, etc.
4) Use accessories and consumables provided with the product in accordance with specifications 
    required by the company. When specifications other than required ones are used, 
    it is at risk for accident.
5) When power cord, plug or socket is broken or damaged, do not use the product but make 
    inquiries to the company. It is at risk for (electric) shock and fire.
6) Hold the plug to unplug the power cord and do not hold the plug with a wet hand. 
    Also, do not use the product when the power plug is loose. It is at risk for electric shock and fire.
7) Do not locate near heating instruments or put a candle or a light around the product. It is at risk for fire.
8) Watch carefully whether the elderly and the infirm, the disabled or children are close to where 
    the product is located and do not leave children alone.
9) Be careful not to drop foreign substances such as water and saline solution on implant engine 
    controller and foot switch. When the product does not work normally or foreign substances are 
    in the product, do not operate the product but make inquiries to the company.
10) Use the product only with intended use written in this manual and do not use in any way 
    which is not recommended by the manufacturer. 
    The company is not liable for accident resulting from not observing the instruction manual.
11) Exterior equipment to connect to signal input section, signal output section and other connections 
    should comply with relevant IEC standards.
12) To avoid the risk of electrical shock, this product must only be connected to a power source 
    with protective earth.
13) Warning statement referring to the necessity for periodic checking or replacement of such an 
    additional power source
14) Contain an instruction not to position the product so that it is difficult to operate the disconnection 
    device.
15) Don’t use the foot switch in the places that there is water, like the emergency room or the 
    operating room.
16) Do not modify this equipment without authorization of the manufacturer.
17) Do not use a mobile phone or wireless RF communication device near the electric medical device 
    to prevent adverse effect on the device.
 

Chapter 2. Safety (Warnings and Cautions)

4/24

Summary of Contents for ELEC ENGINE ISE-170L

Page 1: ...Dental Engine for Implant Surgery ISE 170C ISE 170L INSTRUCTIONS FOR USE...

Page 2: ...tist Catalogue number Serial number Manufacturer Authorized representative in the European Community Date of manufactured BF type applied part Alternating current Keep dry Caution Consult Instruction...

Page 3: ...apter 3 Product Description Chapter 4 Installation Chapter 5 Operation Chapter 6 Maintenance Chapter 7 Trouble Shootings Chapter 8 Accessories and Service Chapter 9 Electromagnetic Compatibility Chapt...

Page 4: ...en performing dental implant procedures 1 3 Users Only qualified dentists may use this device in a professional environment 1 4 Indications of Use 1 Where there is an absence of gum or teeth caused by...

Page 5: ...ully whether the elderly and the infirm the disabled or children are close to where the product is located and do not leave children alone 9 Be careful not to drop foreign substances such as water and...

Page 6: ...ant surgery Ensure that the product is use in accordance with the intended use and correct procedure 2 With priority to patient s safety use the product with good care 3 Read the instruction and thoro...

Page 7: ...PUSH Display Irrigation fixing part Irrigation device switch Motor connection M COOLANT P GEAR RATIO TORQUE SPEED FOR REV S 6 24 Irrigation hanger connection part Power cord connection part Gear Ratio...

Page 8: ...ratio currently selected for use Indicates injection a mount of water in 5 levels Indicates the status of the motor LED Indicates direction of motor s rotation and flickers during operation of engine...

Page 9: ...cription 3 1 2 Foot switch FS V1 3 1 3 Motor ISM B70L Optic LED Handpiece connection Motor connection Coolant button Operation button Hanger hole Foot switch cable Foot switch connector Rotation butto...

Page 10: ...sumption 100 120 220 240 V 50 60Hz 150VA Max Coolant flow rate Fuse Dimension 130 ml min 2 T2AL 250V 300 230 135 Width Length Height Speed Max Torque Max Current 200 40 000 rpm 7 Ncm Speed control 3 F...

Page 11: ...Used in connection with a micromotor Handpieces are not included in the this package Chapter 3 Product Description 3 4 Environmental Conditions Storage Relocation Operation 1 Storage conditions Temper...

Page 12: ...by connecting Hanger bolt Insert Foot switch hanger into Hanger hole Fix by connecting Hanger bolt Fit the motor connector into groove Connect the motor connector CAP Be careful to fit into the conne...

Page 13: ...ce Irrigation tube Tube clip Irrigation tube Tube clip Motor cable Irrigation tube coolant clip Attach the motor cable and irrigation tube in regular intervals using the coolant clip Open Irrigation c...

Page 14: ...Hook in the coolant container on the bottle holder Close the tube clip Open the tube clamp before start up 4 4 Connection of power cord and foot switch 4 5 Disconnection Connect power cable to power...

Page 15: ...e in 2 3 seconds When load reaches the maximum value of preset torque during use motor stops rotating It stops rotating upon releasing Foot switch A user selects a program necessary for surgery with t...

Page 16: ...ds the frame with the memory number will flash alternately and the frame will be off with a beep sound then the saving is complete 5 3 2 Saving data Program Drilling Tapping Remove tap Implant Remove...

Page 17: ...RATIO 5 6 Setting direction of motor rotation The initial setting is Forward direction and Reverse is selected upon pressing the button The letter and arrow are turned on upon selecting Reverse with b...

Page 18: ...er function or when the motor operates Torque Button Control Button Chapter 5 Operation TORQUE LCD Display 5 9 Change in speed Main function Speed section on the display flickers upon pressing Speed b...

Page 19: ...5 12 Operation of implant engine Main function Implant engine operates upon completion of all settings When motor operates by pressing Foot switch the letter R on display and the surrounding border fl...

Page 20: ...the operating condition 3 Repeat the cleaning process if foreign substance is found 4 Repeat the above procedure for every single use Clean the product before and after use 6 3 Sterilization 6 4 Chang...

Page 21: ...sking for repair Replacing fuse Checking the connection Asking for repair Inaccurate connection of power cord Breakdown of foot switch Breakdown of power cord Breakdown of fuse Motor does not operate...

Page 22: ...d Made in Republic of Korea Factory 22 Maeyeo ro 1 gil Dong gu Daegu 41059 Republic of Korea 82 53 650 1000 8 3 Warranty Warranty period of the product Life of components and replacement cycle Implant...

Page 23: ...lass A complies The product use RF energy only for its internal function Therefore its RF emissions are very low and not likely to cause any interference in nearby electronic equipment The product is...

Page 24: ...s 150 kHz to 80 MHz 6 Vrms in ISM bands 150 kHz to 80 MHz 80 AM at 1 kHz 30 A m Magnetic fields generated by the mains frequency should be at levels characteristic of a typical location in a typical c...

Page 25: ...l 10 1 1 Disposal of Main controller and foot switch and motor All packaging materials have been selected according to environmentally compatible and disposal aspects and can be recycled Please send o...

Page 26: ...nd production of this medical device 22 Maeyeo ro 1 gil 41059 Republic of Korea Tel 82 53 650 1000 Fax 82 53 650 1001 Web www micronx co kr Karl Marx Str 6 16540 Hohen Neuendorf Germany Tel 49 0 3303...