MR380-1-3 Installation
3.4.1.
Electrical Connections
Figure 7. Front Panel Outputs of MR380-1-3 Controller
The table above depicts the pinouts for the MR380-1-3 controller, and the state of each
terminal when an E-stop switch is on or off. For powering the controller, +24 VDC is supplied
to terminal 1 and grounded using terminal 2. For typical E-stop operation, connect to
terminals 5 and 6 or terminals 8 and 9.
The contact on the controller module uses a Phoenix Contact screw terminal. For more
information, consult Controller specifications given in
Section 6.1
. If connectors are lost or
damaged, contact Micronor Sales for replacement details.
MR380-1-3 Fiber Optic Controller State Table
Terminal
Description
1
+24 VDC Power Supply
Module
Powered
Module Not
Powered
2
Ground Input
Switch
ON
Switch
OFF
Switch
ON/OFF
3
Digital 24V Normally High
LOW
HIGH
-
4
Digital 5V Normally High
LOW
HIGH
-
5
Normally Closed Relay Contact 2
OPEN
CLOSED
OPEN
6
Common Relay Contact 2
-
-
-
7
Normally Open Relay Contact 2
CLOSED
OPEN
CLOSED
8
Normally Closed Relay Contact 1
OPEN
CLOSED
OPEN
9
Common Relay Contact 1
-
-
-
10
Normally Open Relay Contact 1
CLOSED
OPEN
CLOSED