LED Indication 

Please refer to the following table for LED indication of SP373 Series 

LED 

Status 

Indication 

Steady   

The Power is on 

PWR 

Off 

The Power is off 

Steady 

Connection at speed of 100Mbps 

100 (Mbps) 

Off 

Connection at speed of 10Mbps 

Steady 

A valid network connection established 

Flashing Transmitting 

or receiving data 

LNK/ACT 

Off 

Neither valid network connection established nor 
transmitting/receiving data. 

Steady 

Connection in full duplex mode 

Flashing Collision 

occurred 

FDX/COL 

Off 

Connection in half-duplex mode 

 

First 2 LEDs 

indicated FX port status 

Second column 2 LEDs 

indicated TX port status. 

 

DIP Setting of SP373 Series

 

Port settings are made very simple by means of a DIP (Dual Inline Package) switch at the rear panel 

of the module. The default setting is auto negotiation and LFPT (Link-Fault-Pass-Through) enable as 

shown below. A connected network device might fail to respond to the auto negotiation mechanism 

due to various reasons, and therefore, this DIP switch allows user to manually adjust the TX/RX 

speed and duplex modes. 

There are six pins on the DIP switch for port settings. Refer to the table below for more details. 

6

 

Summary of Contents for SP362B Series

Page 1: ...User s Manual SP362B SP363B SP373 Series Twist Pair to Fiber Ethernet Media Converter http www micronet info...

Page 2: ...e expansion of the Ethernet network SP373 Series Converter features a RJ45 jack and an ST SC MT RJ VF 45 fiber optic connectors connecting the 10 100Mbps network to the 100BASE FX fiber optic network...

Page 3: ...er multi mode SP362B or single mode SP363B fiber accommodating SC connector For the TX port it uses RJ 45 connector and supports Auto Uplink Cable Connection of SP362B Port type Cable Type Max Length...

Page 4: ...llision occurred FDX COL Off Connection in half duplex mode Steady Receiving data RX Off No reception Steady Transmitting data TX Off No transmission DIP Setting of SP362B SP363B Port settings are mad...

Page 5: ...raight through or cross over cable It will automatically detect the type of cable and link the connection Link Fault Pass Through When cable in one end is OUT disconnected damaged at fault it will inf...

Page 6: ...occurred FDX COL Off Connection in half duplex mode First 2 LEDs indicated FX port status Second column 2 LEDs indicated TX port status DIP Setting of SP373 Series Port settings are made very simple b...

Page 7: ...or half duplex mode y Toggle on Pin 5 to force the FX port at full duplex mode Or toggle off Pin 5 for half duplex mode Connect the converter to the power again The new setting will come into effect t...

Page 8: ...or 10 125 m single mode LED INDICATIONS Power Speed Link Activity Full Duplex Collision MAX DISTANCE 2km 15 40 and 75km FILTERING FORWARDING RATE 10Mbps 14 880pps 14 880pps 100Mbps 148 800pps 148 800...