LED Indication
Please refer to the following table for LED indication of SP362B/SP363B
LED
Status
Indication
PWR
Steady
The Power is on
Steady
A valid network connection established on TX port
LNKC
Off No
connection
Steady
A valid network connection established on Fiber port
LNKF
Off No
connection
Steady
Connection in full duplex mode
Flashing Collision
occurred
FDX/COL
Off
Connection in half-duplex mode
Steady Receiving
data
RX
Off No
reception
Steady Transmitting
data
TX
Off No
transmission
DIP Setting of SP362B/SP363B
Port settings are made very simple by means of a DIP (Dual Inline Package) switch at the front panel
of the module. The default setting is auto negotiation as shown below. If the Pin 1 is on, it means the
fiber port will automatically choose Full Duplex or Half Duplex. User could toggle off Pin 1 to force the
fiber port at Full Duplex. Pin 2 is now reserved for future use.