![MicroNet SP1678A User Manual Download Page 92](http://html1.mh-extra.com/html/micronet/sp1678a/sp1678a_user-manual_1787939092.webp)
91
Password:
Confirm Password:
FEL2SW-26(alarm-sms)# set phone-number 1 0968777777
show
Syntax
: show
Description
: The Show here is to display the configuration of SMS trap event.
Argument
: None.
Possible value:
None.
Example:
FEL2SW-26(alarm-sms)# show
SMS Server : 192.168.1.7
Username :
Password : ****************
Mobile Phone 1: 0968777777
Mobile Phone 2:
Mobile Phone 3:
Mobile Phone 4:
Mobile Phone 5:
Mobile Phone 6:
4.3.4 autologout
autologout
Syntax
: autologout <time>
Description
: To set up the timer of autologout.
Argument
: <time>: range 1 to 3600 seconds, 0 for autologout off, current setting is 180 seconds.
Possible value:
<time>: 0, 1-3600
Example:
FEL2SW-26# autologout 3600
Set autologout time to 3600 seconds
4.3.5 bandwidth
disable egress-rate
Syntax
: disable egress-rate <range>
Description
: To cancel the egress-rate of the port.
Argument
: <range>:syntax 1,5-7, available from 1 to 24
Possible value:
<range>: 1 to 24
Example:
FEL2SW-26(bandwidth)# disable egress-rate 1-8
disable ingress-rate
Syntax
: disable ingress-rate <range>
Description
: To cancel the Ingress-rate of the port.
Argument
: <range>:syntax 1,5-7, available from 1 to 24
Possible value:
<range>: 1 to 24
Example:
FEL2SW-26(bandwidth)# disable ingress-rate 1-8