![MicroNet SP1678A User Manual Download Page 111](http://html1.mh-extra.com/html/micronet/sp1678a/sp1678a_user-manual_1787939111.webp)
110
Possible value:
None
Example:
FEL2SW-26(mirror)# show
Mirror Mode : rx
Monitoring Port : 2
Monitored Port : 3 4 5 7 10
FEL2SW-26(mirror)#
4.3.19 port
clear counter
Syntax
: clear
counter
Description
: To clear all ports’ counter (include simple and detail port counter) information.
Argument
: None
Possible value:
None
Example:
FEL2SW-26 (port)# clear counter
disable flow-control
Syntax
: disable flow-control <range>
Description
: To disable the flow control function of the port.
Argument
: <range>: syntax 1,5-7, available from 1 to 24
Possible value:
<range>: 1 ~ 24
Example:
FEL2SW-26 (port)# disable flow-control 6
disable state
Syntax
: disable state <range>
Description
: To disable the communication capability of the port.
Argument
: <range>: syntax 1,5-7, available from 1 to 24
Possible value:
<range>: 1 ~ 24
Example:
FEL2SW-26 (port)# disable state 12
enable flow-control
Syntax
: enable flow-control <range>
Description
: To enable the flow control function of the port.
Argument
: <range>: syntax 1,5-7, available from 1 to 24
Possible value:
<range>: 1 ~ 24
Example:
FEL2SW-26 (port)# enable flow-control 3-8
enable state
Syntax
: enable state <range>
Description
: To enable the communication capability of the port.
Argument
: <range>: syntax 1,5-7, available from 1 to 24
Possible value:
<range>: 1 ~ 24
Example:
FEL2SW-26 (port)# enable state 3-12