PRODUCT INTRODUCTION 

Protect Functions

〗 

Protect  functions  can  prolong  the  air 

conditioner’s  service  life  and  provide  more

 

comfortable airflow. 

Delay-starting protection for the compressor

 

The compressor will restart working at least 3 minutes (5 minutes in heating mode) after

 

being turned off to keep the pressure balance of the cooling system. 

Remarks: 

There will be 1 minute for the compressor to work after the unit is electrified for

 

the first time. 

Freeze-prevention

 

To  prevent  indoor  heat  exchanger  freezing  in  cooling  and  dehumidification  operation,

 

compressor  or  outdoor  fan  may  stop  running;  indoor  fan  speed  will  be  adjusted  to  a

 

higher gear automatically. 

Dry for enzyme-prevention 

(optional)

 

Indoor  fan  motor  will go  on  running  for  3  minutes  at  low  fan  speed when  turned  off  in  cooling 

mode in order to keep dry condition inside the unit. 

Reset power or Auto restart (alternative)

 

Reset power: When there is a power suspension, air conditioner will automatically switch

 

off. When the power is back, the unit will automatically reset power. For energy saving if

 

there is no person in the room, air conditioner will stay in PAUSE status. User needs to

 

turn on Air conditioner by remote controller. 

Auto restart: The unit memories the operation mode, air flow setting, temperature setting

 

etc.,  so  that  should  there be  a  power  failure  when  the  unit is  in  operation, it  will

 

automatically return the same operating conditions when the power is restored. 

Cooling overload working (optional)

 

In cooling operation, if the temperature of outdoor heat exchanger is too high, indoor fan

 

speed will be adjusted to a lower gear automatically and compressor may be stopped. 

Drip proof (optional)

 

In  cooling  and  dehumidification  operation,  louver  blades  can  change  the  position

 

automatically to prevent from dripping. 

Summary of Contents for Environ 1.5T

Page 1: ...ul of sharp edges on the front and rear fins of the unit that could cut and cause serious injury 7 Be careful when lifting the air conditioner to install or remove the unit Always use two or more peop...

Page 2: ...rigerant leakage may be resulted as well Operating instruction Please operate air conditioner in accordance to this manual If the power cable to the unit is disconnected burnt chipped or detached from...

Page 3: ...utlet or breaker Do not under any circumstances cut or remove the third ground prong from the power cord Adapter plug We strongly advise against using an adapter plug or breaker Operating conditions 1...

Page 4: ...e dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures The appliance shall be installed in accordance with nat...

Page 5: ...hen there is operating gas equipment Do not switch on or off the unit by plugging or pulling off the plug or by switching on or off the breaker Do not put anything on the outdoor unit Do not put finge...

Page 6: ...re flammable gas may leak Switch off the unit cut off the power source and contact service agent if there is abnormal phenomenon e g burning smell comes out Do not pull off the power plug or switch of...

Page 7: ...oling mode in order to keep dry condition inside the unit Reset power or Auto restart alternative Reset power When there is a power suspension air conditioner will automatically switch off When the po...

Page 8: ...s Outdoor unit Air inlet back Air outlet Drain pipe Remarks The air conditioner is consisting of indoor unit outdoor unit and remote controller The design and shape are different for different models...

Page 9: ...isplay is for reference only subject to the actual product Remarks 1 Flashing of any indicator means the air conditioner runs abnormally please contact the distributor in time 2 Function a The air con...

Page 10: ...COOL SWEEP DRY mode TIMER indicator Yellow This indicator lights yellow when the unit is in TIMER mode AIR REFRESH indicator Green optional This indicator lights green when the unit is in Air Refresh...

Page 11: ...Set the air conditioner operating in low noise Timer selection Button Press this button to Select timer Remarks CLEAN Button Press this button to turn on self cleaning Function LOCK Button Press this...

Page 12: ...ontroller under the sunlight or near the oven Don t sprinkle water or juice on the remote controller use soft cloth for cleaning if it occurs The batteries must be removed from the appliance before it...

Page 13: ...unit with water or it may cause electric shock 2 Do not clean the remote controller with water 3 Do not clean with alcohol gasoline banana oil or polishing 4 Do not clean the unit violently or it may...

Page 14: ...for Long Time 1 Swing 3 4 hours to dry the internal 2 Stop operation by remote controller then air conditioner Cut off the power source of air conditioner 3 Maintain air filter net 4 Take out batterie...

Page 15: ...ensures high efficiency operation Close Doors and Windows Incoming outdoor air will affect the cooling or heating efficiency Avoid Heat Sources When it is cooling using other heat sources may affect c...

Page 16: ...rs 4 Check whether doors or windows are closed 5 Check whether fan speed or set temperature is improper Remote Controller is in Error The following trouble shooting is normal phenomenon Phenomenon Che...

Page 17: ...nit when the compressor stops there will be a 3 minute delay before restarting Walls carpet furniture or clothes indoors may disseminate peculiar smell There may be gentle rustle sound when the unit s...

Page 18: ......

Page 19: ...Installation Manual...

Page 20: ...d cut and cause serious injury 7 Be careful when lifting the air conditioner to install or remove the unit Always use two or more people for this 8 Always cut off the power of air conditioner before s...

Page 21: ...3 13 14 15 16...

Page 22: ...lt your supply authority for system information The plug shall be accessible after installed the appliance This instruction is subject to change without notice Installation ofAccessories Examine caref...

Page 23: ...ont rear left and right sides must be located in an open area The outlet is proposed to be in open air any obstacle will affect the performances The installing distance must be required as Fig 2 shows...

Page 24: ...tallation board on the wall with M5x30 screws and washer 6 Ensure that there must be at least 4 fixed points in the wall Ensure installation board to horizontal position Drill holes as Fig 4 shows The...

Page 25: ...ut at the below Pipeline Remove the board which is on the chassis Check if the connections are reliable Units connecting wires Fig 6 Drain pipe Mount the indoor unit on the two hooks at the upper part...

Page 26: ...s to prevent from falling In installing or repair tools and components should be prevented from falling Regularly check the reliability of the installation frame TubingConnection Detach the valve cove...

Page 27: ...e plate Close the connection lid screw it tightly and close the inlet grid 2 Outdoor unit Unscrew and dismantle the electronic device lid Fig 13 Dismantle the pressure plate of wire fastener Connect t...

Page 28: ...wn Blue Yellow Green 5 Yellow Green Blue Brown Brown Blue Yellow Green 1 2 Brown 1 Blue N 2 N 3 Yellow Green 3 4 5 1 2 N 3 4 5 Brown 1 N 2 Blue Yellow Green 1 2 N 3 4 5 Brown 1 N 2 3 4 5 Blue Yellow G...

Page 29: ...st be careful do not damage the pipeline and drain pipe Strapping should start from the lower part of the outdoor unit to the indoor unit Fix the PVC tape with adhesive tape to prevent loosing Drainpi...

Page 30: ...e are leakage at all indoors and outdoors connections Put the valve bonnet and valve cover back to the position Narrow tube Wide tube Open Service valve Fig 16 2 Pumping type Make sure that all the tu...

Page 31: ...alve Screw tightly the entire valve bonnet by torque spanner Check with soap water or leak detector whether there are leakage at all indoors and outdoors connections Put the valve bonnet and lid back...

Page 32: ...ry bag Outdoor unit should be placed on blocks Chassis outdoor Elbow joint Fig 18 Drain pipe buy it by user Installation for the cover of valve Optional For the whole unit that individual cover of val...

Page 33: ......

Reviews: