PAGE 27
© 2021 OJ Electronics A/S
Temperature limits (
tLLo
,
tL
h
i
)
These settings allow you to set the minimum and
maximum temperature that the thermostat can operate
inbetween
Operating temperatures:
Temperature limit low (
tLLo
) can be used to secure that
the temperature setpoint is unable to be set below a
specific value Can be set between 0 and 40°C
Temperature limit high (
tL
H
i
) can be used to secure
that the temperature setpoint is unable to be set above a
specfic value Can be set between 0 and 40°C
Note: If the maximum temperature limit is set too high,
sensitive floor types may be permanently damaged.
REMOTE
Access the temperature limit settings:
• Press ” ”for 3 seconds to enter the settings
• Scroll through the settings until either
tLLo
(temperature limit low) or
tL
H
i
(temperature limit high)
appears on the display
• Press ” ”to enter either
tLLo
or
tL
H
i
• Use ”
” or ”
” to adjust the temperature limits
• Return to the settings with ” ”
Menu structure:
tLLo
: 0 40°C
tL
H
i
: 0 40°C