Microlink ML-891X Series Operating Manual Download Page 22

7.<ALARM SETTING> menu operating

Entry <ALARM SETTING> menu

setting

Ref picture 29

In the standby situation, calling“95”,it will entry the main Manu. Move the cursor to <ALARM SETTING>,press 
“IRIS+”to entry the submenu.Ref picture 28

Operation details:
1.Alarm Channel: 

Press “IRIS+”to entry and select alarm channel number, it can select 1-4 alarm channel 

                                       number by shaking the rocker up or down.

2.Alarm Action:

 Press “IRIS+”to entry current channel set, select“yes” or “no” by shaking the rocker up or 

                                   down.

3. Alarm Mode:

 Press “IRIS+”to entry the current channel, which is “always open” or“always close” mode

                                 (set according by the alarm);

4.Output Linkage:

 Press “IRIS+”to entry setting for current channel connecting the alarm signal, which 

                                        include:1-4group cruise setup,1-4 group left-right scan setup,1-4 group pattern setup,
                                       1-220pcs preset and “close”, shaking the rocker up or down could select one of them,
                                        “close”means don’t operate anything. After setting press “IRIS+”for saving and return.

5.Linkage output: 

Press “IRIS+”to entry the linkage output setting, by shacking the rocker up or down can 

                                       select “output 1”or “output 2”.Linkage output function can offer the alarm signal to DVR 
                                       or other device. Set“close” means don’t operate linkage output.

6. Reset delay:

 Setting the interval is 1-255 second between two alarm signal receiving. For example, set 

                                 the time for 10 second, it means it will reset delay automatically when received a alarm 
                                 signal longer than 10 second in the same alarm channel. After reset delay than could receive 
                                 the next alarm signal.

8. <IR LED SETTING> menu operation

Enter <IR LED SETTING> menu

In the standby situation, calling“95”,it will entry the camera main Manu. Move the cursor to <IR LED>

,

press“IRIS+”to entry the submenu.

picture 29
 setting

<IR LED>

Infrared Intelligent High Speed Dome Camera Operating Manual

21

picture 28 

 

setting

 <ALARM>

Summary of Contents for ML-891X Series

Page 1: ...Infrared High Speed Dome Camera Fourth generation IV Operating manual 8891X series Version V2 0 ML...

Page 2: ...instant discharge lightning technology which can prevent the lightning under 500W power surge and other kinds of pulse of high voltage to damage the interior of the camera 4 In order to protect the c...

Page 3: ...6 Boot initialization 2 7 Basic operation 3 AUTOMATIC OPERATION SETTING menu operation 3 1 PRESET POINT setting 3 2 LEFT RIGHT SCAN setting 3 3 CRUISE SCAN setting 3 4 PATTERN SCAN setting 3 5 TIME AC...

Page 4: ...High Speed Dome Camera Operating Manual 3 1 Installation and debugging of Infrared High Speed Dome Camera 1 1 Infrared high speed component name 1 2 Installing hole size figure Whole set size mm Inst...

Page 5: ...ned TO DOME on the right of prevent lighting plate 1 3 5 penetrate the video cable and 485 controls thread from waterproof screw and contact to the corresponding outlet signed OUTPUT LINE on the left...

Page 6: ...output devices Power Supply Video Output Communication Dome Address Communication Protocol Baud Rate Horizontal Rotation Speed Horizontal Rotation Range Vertical Rotation Speed Vertical Rotation Rang...

Page 7: ...tive Resistance turn on the infrared lights and convert black and white images automatically Automatic Focus If the product is set to auto focus mode When the user control PTZ the camera always follow...

Page 8: ...Infrared Intelligent High Speed Dome Camera Operating Manual 7 2 4 Address DIP table 1 means ON 0 means OFF Binary code Address Binary code Binary code Address Binary code Binary code Address...

Page 9: ...code Address Binary code Address Binary code Address Binary code Address Operation instructions As the specific operation ways are different for Variety of controlling equipments please refer to the...

Page 10: ...f operating stuffs name on the left up the screen such as camera name preset name A to B scanning name cruise scanning name and pattern scanning name Current date time surveillance direction ptz locat...

Page 11: ...on not based on the menu Please choose the sections you need Enter camera main menu Under the standby status call 95 enter the camera main menu There are 6 groups As picture 4 function Start 1 4 group...

Page 12: ...elect the preset number up or down the joystick to select 1 220 preset point number 2 Title Press Iris to enter and edit the title up or down the joysticks to choose numbers letters or characters Left...

Page 13: ...ters press IRIS to save after edit then return 3 Set start press IRIS to set scan start move PTZ to choose the start on the left press IRIS again to confirm and return 4 Set stop press IRIS to set sca...

Page 14: ...eset point control lever up and down to choose second 1 255 every group can up to set 32 preset point same with other preset points setting press IRIS to save after edit then return Picture 9 shows 5...

Page 15: ...hoose time number move joystick up or down to choose 1 4 number 2 Start time click IRIS to set start time Dome camera can set time in 24 hours Move joystick up or down to set 00 23 hour number and mov...

Page 16: ...to enter move joystick up or down to choose iris focus close all For example choose iris then lens focus will not change when pan tilt move And the lens will auto focus when operate iris If choose all...

Page 17: ...as Picture15 Detail operations 1 Zooming speed click IRIS to set zooming speed Move the joystick up or down to choose high or low speed Click IRIS to save and return 2 Digital zoom click IRIS to set...

Page 18: ...brighter the image is 6 Digi slow shutter set digital shutter to open or close 7 Day night mode make the camera and IR led change day night mode by force to three modes auto night and day 4 3 WHITE BA...

Page 19: ...to choose the object needed to cover and be sure the object is in the middle of the monitor again click IRIS to set the size of the area It appears a black rectangular area in the middle At this momen...

Page 20: ...one is hardware DIP address there will be a reminder that please set it to be 0 for hardware address first it means 8pcs address DIP need to be moved down on DIP switch board You need to input correct...

Page 21: ...6pcs character Remind entry the new password shaking the rocker up or down can select the figure letter in small or capital symbol and so on to make as your password Shacking by left or right can cha...

Page 22: ...set and close shaking the rocker up or down could select one of them close means don t operate anything After setting press IRIS for saving and return 5 Linkage output Press IRIS to entry the linkage...

Page 23: ...Power cable in short circuit or open circuit Address code protocol baud rate setting is incorrect RS485 length is more than 500m RS485 connection is not good Power is not strong enough Belt is loose o...

Page 24: ...Before using the camera please read the factory settings of the user manual carefully Power AC200V 50HZ Address1 Protocol PELCO D Baut Rate 2400bps...

Reviews: