a high pressure drop. Remember, these tanks
can weigh up to 30 pounds when full of water;
a firm, level area is required.

3. R.O. Manifold Assembly–The manifold can

be installed on either the right or left side of
the under–sink area or a cabinet. The right
side is recommended because all the tubing
will be to the back of the cabinet and out of
the way. Installation in the basement is also an
option, one location is near the laundry/utility
sink where cold potable water and drain access
is handy. The mounting location should allow
adequate clearance and accessibility for
cartridge changes.

4. Feed Water Connection–The Feed Water

Saddle Valve should be located as close to the
manifold assembly as possible. USE A
POTABLE COLD WATER SUPPLY ONLY.
Softened water is preferred as it will extend
the life of the R.O. Membrane.

5. Drain Connection–The waste water must go

to drain through an anti–siphon air gap. The
air gap is provided for in the base of the faucet.
If discharging into a utility sink or standpipe,
an air gap of greater than 1" above the flood
rim must be provided.

Do NOT connect the system drain line to the
dishwasher drain or near the garbage disposal.
Backpressure from these units may cause the
air gap to overflow.

SECTION IV. INSTALLATION STEPS

All plumbing should be done in accordance with
state and local plumbing codes.

NOTE: Some codes may require installation by a
licensed plumber; check with the local plumbing
authority prior to installation.

In restricted under–sink areas, it may be easier to
install the faucet first. Allow adequate tubing lengths
for any final component position.

A. Faucet Installation–The faucet contains an anti–

siphon air gap. While the system is producing
water, the drain water flows from the R.O.,
through the air gap and then to the household
drain. The purpose of the air gap is to prevent
water in the drain from backing up into the R.O.
Drinking Water System.

NOTE: For proper installation the Air Gap
Faucet has a critical level line “CL” marked on its
body and should be mounted so that the “CL” line
is at least one (1) inch (26mm) above the flood
level rim of the sink.

The easiest installation is to use an existing spray
attachment hole. If the spray faucet hole is not
available, then the sink top must be drilled.
Choose a convenient location as described in
Sec. III, C.1, page 4.

1. Mark the location of the center of the faucet

base.

2a. Drilling a stainless steel sink:

•Center punch the hole to provide a starting

point for the drill.

•Start with a smaller drill as a pilot, and then

drill a ½" diameter hole to accept the bolt of
a 1¼" Greenlee Hole Punch (1¼" chassis
punch).

•Clean away any chips.

•Install the punch and tighten the nut to cut

the hole.

•Deburr any sharp edges.

2b. Drilling a porcelain sink:

It is best to use a special 1¼" diameter cutter
designed for porcelain. A carbide tipped
masonry bit is a second choice.

•Place a piece of tape over the area to be

drilled to help prevent chipping.

•Drill a pilot hole for the porcelain cutter. Use

the pilot drill supplied with the kit or a
carbide tipped drill.

•When drilling the 1¼" hole, drill slowly and

carefully; the porcelain chips easily.

•After drilling, clean the area well. Iron

filings, if left in place, can cause rust stains.

2c. Drilling a counter top:

NOTE: The counter top must be less than
1¼" thick. (See Sec. IV, A.2b, page 5.) Treat
ceramic tile as porcelain until the tile is
penetrated, then use the carbide tipped metal
cutter.

Formica counter tops may be drilled with a
good 1¼" wood bit, drilling a 

3

/

32

" pilot hole

will help keep the bit going straight.

Summary of Contents for T.F.C.-25D

Page 1: ...MICROBIOLOGICALLY UNSAFE OR OF UNKNOWN QUALITY WITHOUT ADEQUATE DISINFECTION BEFORE OR AFTER THE SYSTEM MICROLINE REVERSE OSMOSIS DRINKING WATER SYSTEM Model T F C 25D Installation Operation Service Manual This drinking water system is tested and Certified to ANSI NSF Standard 58 for the reduction of Barium Cadmium Chromium Hexavalent Chromium Trivalent Copper Fluoride Lead Mercury Radium 226 228 ...

Page 2: ...ion 7 C Drain Clamp Installation 8 D R O Manifold Assembly Installation 8 E Position the Drinking Water Holding Tank and Make the Final Hose Connections 8 F Start Up 9 SECTION V OPERATION AND MAINTENTANCE 10 A Normal Operation 10 B Changing Filters 10 C Changing the In Line Activated Carbon Post Filter 11 SECTION VI TECHNICAL DATA 11 A Water Quality 11 B Water Quantity 11 C Net Pressure Differenti...

Page 3: ...provides maximum surface area for water production and is less susceptible to fouling by particulate matter turbidity and colloidal materials ACTIVATED CARBON The Activated Carbon Post Filter contains carbon particles with a vast network of pores The tremendous surface area of these pores typically 800 1200 square meters per gram of carbon gives the carbon very good adsorptive sites for substances...

Page 4: ...k INLET 1 4 Red TANK 3 8 Yellow 1 4 Yellow FEED WATER SADDLE VALVE COLD WATER LINE ONLY 1 AIR GAP REQUIRED MOUNT HOLDING TANK ON SHELF OR STRAP BETWEEN FLOOR JOISTS Shelf Or Straps Not Included FLOOR BASEMENT FLOOR NOTE FOR REFRIDGERATOR WATER DISPENSER OR ICE MAKER HOOKUP TEE INTO 3 8 BLUE TUBING TO DISPENSING FAUCET POLYTUBE TEE RO MANIFOLD COVER PLEASE NOTE IF AIR GAP ON FAUCET IS NOT USED IN B...

Page 5: ...ures are for a new Membrane that has been rinsed for 24 hours The production rate of a new Membrane can decrease by 10 per year or more depending upon the scaling and fouling tendencies of the Feed Water 2 Actual capacity measured at 50 psig 77 2 F 818 mg l TDS per ANSI NSF Standard 58 3 5 psig precharge and 40 psig water pressure in tank TABLE B RECOMMENDED OPERATING LIMITS FOR FEED WATER Specifi...

Page 6: ...ith jaws taped to hold faucet 13 Basin wrench or 10 pipe wrench 14 Teflon tape 15 Wide masking tape or duct tape 16 Plastic tubing cutter 17 Extra plastic tubing 18 Low range air pressure gauge 19 Bicycle hand air pump 20 Small bottle of liquid chlorine bleach 21 Graduated measuring cylinder 22 Paper towels wisk broom and assorted clean up materials C Site Selection for Major System Components The...

Page 7: ... gap While the system is producing water the drain water flows from the R O through the air gap and then to the household drain The purpose of the air gap is to prevent water in the drain from backing up into the R O Drinking Water System NOTE For proper installation the Air Gap Faucet has a critical level line CL marked on its body and should be mounted so that the CL line is at least one 1 inch ...

Page 8: ...ing an additional half turn Don t over tighten Rotate the Spout and Body into position Align the Slotted Washer and the Spacer to allow access to the Hose Barbs and tighten the Hex Nut while holding the faucet in alignment with a padded Crescent wrench Do not over tighten B Feed Water Saddle Valve Installation Decide on location Do NOT connect to a hot water feed line If you are not sure of the su...

Page 9: ...Drain Clamp There should be no sag in the line as 3 8 DRAIN CLAMP ASSEMBLY Figure 4 Drain Pipe 1 4 Screw Drain Clamp Front Plate Insert Compression Nut Black Drain Tubing 1 4 Nut Drain Clamp Back Plate Assemble and tighten the brass screw To pierce the tubing turn the Valve Handle fully clockwise inward A small amount of water may escape from the outlet until it is fully pierced When you feel the ...

Page 10: ... Brass Insert Connect to the Feed Water Saddle Valve 3 Locate the Black Drain Tubing Remove the black plug from the fitting labelled Drain on the manifold and insert the tubing Run the tubing along its course to the Hose Barb on the Dispensing Faucet trim to length and connect by firmly pressing over the barb Allow the tubing to relax then press firmly again to insure proper seating 4 Locate the y...

Page 11: ...ter Saddle Valve turning counter clockwise As soon as the water begins to come out of the Dispensing Faucet close the Faucet Let stand for 15 minutes NOTE During this time check the system carefully for leaks At the end of 15 minutes CLOSE the Feed Water Saddle Valve and open the Dispensing Faucet Allow the Holding Tank to completely drain then remove the Sediment Carbon Filter Housing the farthes...

Page 12: ...ded interval for changing the filters not the R O Membrane is every six 6 months Typical T F C Membrane life expectancy is three years Local conditions may dictate more frequent changes NOTE If the R O Membrane is to be replaced see Sec IV F 1 3 page 9 for the proper procedure Use a drip pan to catch any water that may spill when the Filter Housings are removed Refer to Fig 1 page 1 for component ...

Page 13: ...bes to the new Post Filter Refer to Fig 5 above 5 Slowly open the Feed Water Saddle Valve 6 When water begins dripping out of the Faucet in the following order close the Faucet and open the Holding Tank Valve When the Faucet is first opened expect air and carbon fines very fine black powder from the new Post Filter to be rinsed out This is normal for the first tank of water IN LINE ACTIVATED CARBO...

Page 14: ...e and is measured as the amount of water produced in one day It is reported as Gallons per Day gpd or Liters per Day lpd The flow of water to drain is the Reject Water Rate and is measured as Gallons per Day gpd or as Milliliters per Minute ml min Milliliters per minute x 0 38 gallons per day EXAMPLE The drain flow will fill a graduated cylinder to the 150 ml mark in one minute 150 ml min x 0 38 5...

Page 15: ...1 50 11 9 45 0 15 5 15 5 19 2 19 2 22 8 22 8 26 4 26 4 30 1 30 1 33 7 127 6 500 10 2 38 6 13 9 52 6 17 5 66 2 21 2 80 2 24 8 93 9 28 5 107 9 32 1 121 5 1000 8 4 31 8 12 0 45 4 15 7 59 4 19 3 73 1 23 0 87 1 26 6 100 7 30 3 114 7 1500 6 6 25 0 10 2 38 6 13 9 52 6 17 5 66 2 21 2 80 2 24 8 93 9 28 5 107 9 80 27 50 14 3 54 1 18 7 70 8 23 0 87 1 27 4 103 7 31 8 120 4 36 2 137 0 40 6 153 7 500 12 3 46 6 ...

Page 16: ...ane life is unusually short find and correct the problem Replace Membrane Feed Water Saddle Valve is plugged or closed Clogged Sediment Carbon Prefilter or Activated Carbon Post Filter Low water pressure R O Membrane is fouled Plugged In Line Activated Carbon Post Filter Air precharge pressure in Holding Tank is too high Air precharge is too low Air bladder in the Holding Tank is ruptured Holding ...

Page 17: ...Cause Solution Tastes and odors in the Product Water The Product Water and Drain Water lines are reversed No drain flow Drain Restrictor is clogged No drain flow the drain orifice in the Air Gap Faucet is plugged The ASO Valve is not closing New Activated Carbon Post Filter not rinsed completely The Feed Water TDS has increased The Activated Carbon Post Filter is exhausted There is foreign matter ...

Page 18: ...16 MADE IN USA 1 2 3 4 5 6 7 8 9 10 11 12 13 14 17 25 19 EXPLODED VIEW PARTS LIST 15 16 20 21 18 17 22 23 24 ...

Page 19: ... 6 Drain Restrictor 60 GPD 227 lpd Yellow 20 S2004 Inlet Outlet Cap 21 S2009 Self Tapping Screw 22 N1033 Bracket Screw 23 S2014 Mounting Bracket 24 S3072 Wrench for Housing 25 S1405 1 4 3 8 Fitting Wrench 26 S1086 02 1 4 MPT x 3 8 Polytube Connector 27 S7206C 06 In Line Activated Carbon Post Filter OTHER COMPONENTS AS SHOWN IN FIGURE 1 PAGE 1 DRAWING NO PART NO DESCRIPTION 1 S1089 08 Long Reach Ai...

Page 20: ...teration accident misapplication physical damage or damage caused by fire acts of God freezing or hot water All replacement filters and membranes must be Microline filters and membranes or the warranty is void If the unit is altered by anyone other than Microline the warranty is void To obtain warranty service A contact your local dealer who supplied the unit or B contact the factory for the deale...

Reviews: