background image

WatchBP Office Central

EN

1

Cardiovascular Screening Solution for: 
-Central blood pressure measurement
-Ankle Brachial Index assessment

-Atrial fibrillation detection

-Simultaneous assessment of the Inter-Arm Blood 

Pressure Difference

Instruction Manual

WatchBP Office Central

Summary of Contents for WatchBP Office Central

Page 1: ...ascular Screening Solution for Central blood pressure measurement Ankle Brachial Index assessment Atrial fibrillation detection Simultaneous assessment of the Inter Arm Blood Pressure Difference Instruction Manual WatchBP Office Central ...

Page 2: ...alBloodPressureMonitor AValidationReportforMicrolifeWatchBPOfficeCentral AmJHypertens 2013 26 42 50 2 Stergiou G S etal Diagnosticaccuracyofahomebloodpressuremonitortodetectatrialfibrillation JHumHypertens 2009 23 654 8 3 Wiesel J etal Detectionofatrialfibrillationusingamodifiedmicrolifebloodpressuremonitor AmJHypertens 2009 22 848 52 4 NICE WatchBPHomeAforopportunisticallydetectingatrialfibrillat...

Page 3: ...ode 15 16 Skippingthecountdowntime 17 Settingmeasurementintervals 17 ABI mode 18 19 SpecialFunctions Centralbloodpressure 20 Centralpulsepressure 20 Meanarterialpressureandpulsepressure 21 Appearanceoftheatrialfibrillationindicator 22 Aboutatrialfibrillation 23 Inter armdifference IAD 23 ABI AnkleBrachialIndex 24 Hidingmeasurementvalues 25 Viewingandtransferringmeasurementdata In SCREEN mode 26 In...

Page 4: ...CREEN ABI CENTRAL SCREEN MAP IAD I Oswitch MainAdaptorSocket BatteryCompartment CuffSocket L CuffSocket R Recharge Indicator Display M Button Memory Mode Switch Start Stop Button Productdescription Nameofparts SerialPort ...

Page 5: ...Power Atrial Fibrillation Detection Central Systolic Pulse Pressure L R Cuff Supine Position Reminder Hide Display Memory Mode ABI indicator and Pulse Rate Battery Symbol Value for Left Arm Systolic Value Diastolic Value Inter arm Difference Value for Right Arm Systolic Value Diastolic Value Display ...

Page 6: ...eDevice ACAdaptorX1 Input 100 240V 50 60Hz0 48A Output 7 5V2A Cuffforupperarm M Lsize 22cm 42cm X2 InstructionManual QuickStartGuide AUSCULT ROUTINE SCREEN ABI CENTRAL SCREEN MAP IAD Cuffforankle Msize 22cm 32cm X1 IN DE X LI N E 8 LEF SerialPortConnectingCable ...

Page 7: ...dedwithinthe standardpackageoftheWatchBPOfficeCentral Fittingthecuffproperly 1 Placethecuffovertheleft orright upperarmsothat theairtubeandarterymarkarrowpointtowardsthe lowerarm 2 Wrapthecuffaroundthearm Makesurethatthe loweredgeofthecuffliesapproximately2cm inch abovetheelbow Removeallclothingcoveringorconstrictingthe measurementarmbeforeapplyingthecuff Connectthecufftothedevicebyinsertingthecuf...

Page 8: ... 42cm 8 7 16 5inches Withairtube130cm PleasecontactMicrolifeoritsdistributortopurchaseL XLsizeorothersizecuffs M Mediumsize standarddelivered 22 32cm 8 7 12 6inches Withairtube200cm Forupperarm Forankle L Largesize tobeordered 32 42cm 12 6 16 5inches Withairtube200cm Rigidcuff F ...

Page 9: ...cuffontheleg Makesuretheedgeof theanklecuffliesapproximately2to3cm to1inch abovetheankleandnoticethatthearterymarkisonthe posteriortibialartery posteriortibialartery 2 3cm 3 4to1inch 3 Wrapandtightenthecuffaroundtheleg 4 Leavealittlefreespacebetweenthelegofthepatient andthecuff Twofingersshouldfitbetweenthelegand thecuff ...

Page 10: ...nt Selectthearmwiththehigherbloodpressurevalueas determinedwiththe SCREEN mode Selectanoperationmode TheWatchBPOfficeCentraldeviceincludesthreeoperation modes ABI CENTRAL and SCREEN Usethe ModeSwitchtoselectthedesiredmode ENTRAL SCREEN ABI CENTRAL SCREEN ABI CENTRAL SCREEN ABI CENTRAL SCREEN ABI CENTRA ...

Page 11: ... 30 45or60secondsinCENTRALmode Pleasesee Setting measurementintervals atpage17 1 15seconds 2 secondintervalsondefault Ateachmeasurementbrachial bloodpressureismeasuredfirst thereafterthecuffpressure willbeholdaround60mmHgfor30secondsforassessing thecentralbloodpressurevalue thereadingsofthetwo brachialbloodpressurevaluesareaveragedanddisplayed andthereadingsofthetwocentralbloodpressurevaluesare av...

Page 12: ...otharms simultaneously fordeterminingthearmwiththehighest bloodpressurevalueandrevealingthepossiblepresenceof peripheralarterialdisease Thisprocedureisrecommended bytheESHandAHAtoperformatapatient sfirstvisittothe GP spracticeorhospital SCREEN mode Select SCREEN modetoperformfully automatedtriple measurementsonbotharms EEN ABI CENTRAL SCREEN ...

Page 13: ...nute intervals Afterthelast measurementtheaverageofthreebloodpressurevalues isdisplayedontheLCDscreen Themeasuringintervalsarefixedatoneminutein SCREEN mode Theintervaltimecanbeshortenedby pressingtheStart Stopbuttonduringthecountdownperiod Thearmwiththehigherbloodpressurevalueshouldbetakenfor ABImeasurementorfuturebloodpressuremeasurements 60seconds 60seconds 1 2 3 F F ...

Page 14: ...uff 4 Inflationbyfuzzylogic Thedevicewilladjustinflation pressurebyfuzzylogictechnologyinordertodetermine theoptimalinflationpressure 5 Startmeasurements PresstheStart Stopbuttonto startthemeasurementsequence 2 Applythecuff Properlyfitonecufftoeachofthe patient sarms ABI CENTRAL SCREEN ABI CENTRAL SCREEN ABI CENTRAL SCREEN Takingbloodpressuremeasurements 60 second countdown F ...

Page 15: ...ed Ifthe3rd measurementsiscancelledbypressingtheStart Stopafterthe2nd measurement theaveragesarecalculated andsavedtothememoryaswell Pressthe M buttonto displaytheaveragevalue Pressthe M buttonagainto seethe2ndand1stmeasurementagain 60 seconds Takinglessthanthreemeasurements Themeasurementprocedurecanbestoppedatanytime bypressingtheStart Stopbuttonin SCREEN mode ThedeviceentersStandbymodeandtherem...

Page 16: ...kofthedevicetotheON position 3 Switchto CENTRAL mode 4 Selectthepreferredmeasurementarm Leftor Right Pressandholdthe M buttonfor3 seconds 2 Applythecuff Properlyfitonecufftothepreferred measurementarm Pressandholdfor3 seconds Additionalvisualinstructioncanbefoundonthecuff ABI CENTRAL SCREEN ABI CENTRAL SCREEN ABI CENTR F ...

Page 17: ...cewill taketwoconsecutivemeasurementswith15second intervalsinbetweenondefault 15seconds 1 2 Themeasurementintervalscanbesetto15 30 45or 60secondsinCENTRALmode PleaseSee Settingup measurementintervals onpage17 8 Inflationbyfuzzylogic Thedevicewilladjust inflationpressurebyfuzzylogictechnology 9 Theaveragevalueofthemeasurements Theaveragevaluesofboththebrachialand centralbloodpressurewillbedisplayed...

Page 18: ...ngtheStart Stopbuttonafterthecompletionofmeasurements Thedevice willautomaticallyswitchtoStandbymodeifleftunattendedforfive minutes Skipthecountdowntimeand beginmeasurement Standbymode Settingmeasurementintervalsin CENTRAL mode 1 PressandholdtheStart Stopbuttonfor3seconds Pressandholdfor3 seconds 2 Pressthe M buttontoadjustthemeasurement interval thenpresstheStart Stopbuttontoconfirm 15 30 60 45 T...

Page 19: ...tliedown 4 Applythecuff Properlyfitthearmcufftotheupper armandtheanklecufftothelegofthepreferred measurementsideofthebody Thepreferredarmisthe armwiththehigherbloodpressurevalue whichcanbe determinedin SCREEN mode 5 Makesuretheupperarmcuffisconnectedtotheleftcuff socketandtheanklecuffisconnectedtotherightcuff socket Additionalinstructioncanbefoundonthecuff ABI CENTRAL SCREEN ABI CENTRAL SCREEN ABI...

Page 20: ...nology 8 Displayofthemeasurementvalues Themeasurementvalueswillbedisplayedandthe Ankle brachialindexisautomaticallycalculatedwhenthe measurementiscompleted TheAnkle brachialindexandthebloodpressurevalue displayfirst thebrachialindexvalueisreplacedbythe pulsevaluefor3seconds Allthevaluesaresavedautomatically ABI INDEX ABI ABI Taking bloodpressuremeasurements cont ...

Page 21: ...ermined1 AccuracyoftheWatchBPOfficeCentral Theaccuracyofcentralbloodpressuremeasurement performedwithanautomatedoscillometricdevicecanonly reliablybedeterminedagainstintra arterialbloodpressure measurement TheWatchBPOfficeCentralhasbeenvalidated againstsimultaneousrecordedintra arterialbloodpressure measurementin85subjectsandshowedhighaccuracy2 CentralPulsePressure CPP CentralPulsePressurebythismo...

Page 22: ...very5seconds PulsePressure PP Thismeasurementdeviceprovidesthepulsepressure PP ofthepatient pulsepressure systolic diastolicpressure EachmeasurementincludesthecalculationofasinglePP value Theaveragemeasurementwilldisplaytheaverage PPvalue WhenviewinginMemorymode thePPvaluewill bedisplayedwiththesystolic diastolic pressureonceevery 5seconds TheMeanArterialPressure MAP inthisdeviceisdeterminedfromth...

Page 23: ...Diagnosticaccuracyofahomebloodpressure monitortodetectatrialfibrillation JHumHypertens 2009 23 654 8 Thisdevicedetectsatrialfibrillation amajorcauseofstroke Notallriskfactorsforstroke includingatrialflutter maybe detectedbythisdevice Thisdevicemaynotdetectatrialfibrillationinpeoplewith pacemakersordefibrillators F F AfibDetector Thedevicecanscreenforatrialfibrillationduringblood pressuremeasuremen...

Page 24: ...few minutes todaysorweeksandevenyears Atrialfibrillation cancausebloodclotsintheupperchambersoftheheart theatria Theseclotscanbreakoffandflowtothebrain causingastroke Withtherighttreatment thechanceofstrokecanbe reducedbytwo thirds SpecialFunction cont Determinetheproperarmandinter arm difference Ifthebloodpressuredifferencebetweentwoarmsis more than20mmHgforSystolicor10mmHgforDiastolicatallthree ...

Page 25: ...edInordertodetermineABI Ankle BrachialIndex Theankle brachialindex ABI isthencalculatedusing thequotientofthesystolicpressurevaluefromtheleg measurementandthesystolicpressurevaluefromthearm measurement Alowankle brachialindex ABI isindicativeofsystemic vasculardisease andplacesapatientinthehigh risk category ABI INDEX ...

Page 26: ...the M button for7moresecondsuntilOnorOffflashes 2 SelectONorOFF Pressthe M buttonagainto turnthe Hide functionONorOFF 3 Confirm PressStart Stoptoconfirmthesetting Pressandholdfor7 seconds Thedefaultsettingof Hide issetat ON inboth SCREEN modeand CENTRAL ThisfeatureisavailableinbothSCREENmodeand CENTRALmode Whenthe Hide functionisON onlytheaveragevalues aredisplayedaftertheconsecutivemeasurementsan...

Page 27: ...dualmeasurements Allindividual readingscanbeviewedbyrepeatedlypressing the M button Thedisplaywillflashanumber beforethereadingto indicatethesequenceofthe measurement 10 seconds 4 Valuesoftheindividualmeasurement includingPP andMAPvalues willbedisplayedintheorderlistedin step2 1 2 3 SCREEN mode 1 Viewingtheaverageofallmeasurements Whenthelastmeasurementisperformedin SCREEN mode pressthe M buttonto...

Page 28: ...idualmeasurements Allindividual readingscanbeviewedbyrepeatedlypressingthe M button Thedisplaywillshowanumberbefore thereadingtoindicatethemeasurementsequence 4 Thedeviceswitchesthedisplayforvaluesofthe individualmeasurement includingPP MAP CBPand CPPvalues 1 2 CENTRAL mode 1 Viewingtheaverageofallmeasurements Whenthelastmeasurementisperformedin CENTRAL mode pressthe M buttontodisplaytheaverageof ...

Page 29: ...yed Thereisonlyonesetofmemorycapacityinthedevice Only thelastmeasurementswillbesavedinthememory Thememorywillbedeletedwhenthepoweristurnedoff ABI mode 1 Whenthelastmeasurementisperformedin ABI mode pressthe M buttontodisplaytheresultoftheABI measurement 2 ViewingtheAnkle brachialindex ABI AtfirsttheINDEXicon theABIandthebloodpressure valueswillbedisplayed ABI INDEX ABI F F ...

Page 30: ...nisfinished besuretorestart thecomputerbeforeyoustartworkingwiththe program SystemRequirements 550MHzCPU 256MBMemory 1024x768pixel resolution 256color CD ROMdrive 1freeUSBport 40MBfreeharddisk space MicrosoftWindowsXP Vista Win7 System Requirements 550MHz CPU 256MB Memory 1024x768 pixel resolution 256 color CD ROM drive 1 free USB port 40MB free hard disk space Microsoft Windo XP Vista Win7 Instal...

Page 31: ...ds Performameasurement Click Measure Stopameasurement Click Stop Storedata Click Save Close Click Close Pleasereadthesoftwaremanualtoknowmoredetailsofthesoftwareoperationcommands Refertothesoftwareusermanualfordetailedinformationandinstructions ...

Page 32: ...onlyusetheMicrolifeadaptorsuppliedwiththe devicetorechargethedevice 1 PlugtheadaptercableintothePowerPlugofthe WatchBPOfficeCentraldevice 2 Plugtheadaptorplugintothewallsocket When thepoweradaptorisconnected nobatterypoweris consumed Firsttimeuse chargethe batteriesuntiltherecharge indicatorturnstogreen Anorangerechargeindicator meansrechargeinprogress Agreenrechargeindicator meansrechargeis compl...

Page 33: ...isfullydischarged Rechargetherechargeablebatterybyplugginginthe powersupply Cuffdoesnotinflateproperly Looseconnectionofthetube Makesurethetubeofthecuffissecurelyconnectedtothe device Leakageofthetubeor bladder Checkforcracksonthetubeorthebladder Pleasecontact Microlifecustomerserviceforthisissue Noresultdisplayedbetween measurements TheHidefunctionisactivated Disable hide function ...

Page 34: ...usual pleasereadthrough theinformationinthisinstruction manualcarefully Error Description Potentialcauseandremedy Err1 Signaltooweak Thepulsesignalsonthecuff aretooweak Re position thecuffandrepeatthe measurement Err2 Errorsignal Duringthemeasurement errorsignalsweredetected bythecuff causedfor instancebymovementor muscletension Repeatthe measurement keepingyour armstill Errormessages F F ...

Page 35: ...signalsweredetected bythecuff causedfor instancebymovementor muscletension Repeatthe measurement keepingyour armstill Err3 Nopressurein thecuff Anadequatepressure cannotbegeneratedin thecuff Aleakmayhave occurred Replacethe batteriesifnecessary Repeatthemeasurement Err5 Abnormalresult Themeasuringsignalsare inaccurateandnoresult canthereforebedisplayed Readthroughthechecklist forperformingreliable...

Page 36: ...rr15 Abnormal resultofCentral bloodpressure reading Themeasuringsignalsare inaccurateandtherefore noresultcanbedisplayed Readthroughthechecklist forperformingreliable measurementsandthen repeatthemeasurement HI Pulseorcuff pressuretoo high Thepressureinthecuffistoo high over300mmHg OR thepulseistoohigh over 200beatsperminute Relax for5minutesandrepeatthe measurement LO Pulsetoolow Thepulseistoolow...

Page 37: ...facturercannot beheldliablefordamagecausedbyincorrectapplication Observethestorageandoperatingconditionsdescribedin the Technicalspecifications sectionofthismanual Ensurethatchildrendonotusethedeviceunsupervised somepartsaresmallenoughtobeswallowed Onlyactivatethepumpwhenthecuffisinstalled Donotusethedeviceifyouthinkitisdamagedorif anythingappearsunusual Readthefurthersafetyinstructionsintheindivi...

Page 38: ...edforaccuracyevery2yearsoraftermechanical impact e g beingdropped PleasecontactMicrolifeto arrangeforanaccuracytest Cleaningthecuff DONOTwashthecuff DONOTironthecuffcover Devicecare Cleanthedevicewithasoft drycloth Disposal Batteriesandelectronicinstrumentsmust bedisposedofinaccordancewiththelocally applicableregulations andnotasdomestic waste ...

Page 39: ...99mmHg Resolution 1mmHg Staticaccuracy pressurewithin 3mmHg Pulseaccuracy 5 ofthereadoutvalue Voltagesource Rechargeablebatterypack 4 8VC3500mAh MainsadapterDC7 5V 2A ReferencetoStandards Devicecorrespondstotherequirementsof thestandardfornon invasivebloodpressure monitor EN1060 1 EN1060 3 EN1060 4 IEC60601 1 IEC60601 1 2 Electromagnetic compatibility Devicefulfillsthestipulationsofthestandard IEC...

Page 40: ...aone yearguarantee fromthedateofpurchase Thisguaranteeis validonlyonpresentationoftheguarantee cardcompletedbytheownerconfirmingdateof purchaseorpurchasereceipt Product WatchBPOfficeCentral ProductNumber TWIN200CBP Date Name Address Date Telephone E mail Guaranteecard ...

Page 41: ...mail watchbp microlife ch www watchbp com Asia MicrolifeCorporation 9F 431 RuiGangRoad NeiHu Taipei 114 Taiwan R O C Tel 886 2 8797 1288 Fax 886 2 8797 1283 Email watchbp microlife com tw www watchbp com North Central SouthAmerica MicrolifeMedicalHomeSolutions Inc 2801YoungfieldSt Suite241 Golden CO80401 USA Tel 13032742277 Fax 13032742244 Email watchbp mimhs com www watchbp com ...

Reviews: