7. Bluetooth® Function

This device can be used in conjunction with a smartphone running

the «Microlife Connected » App. The Bluetooth® 

connection is automatically active 

CK

 after the measurement has 

been completed.

To manually activate the Bluetooth®, press START/STOP Pad 

1

 

for 4 seconds until the Bluetooth symbol starts flashing 

CK

.

For more detailed information visit www.microlife.com/connect.
8. PC Link Functions

This device can be used in conjunction with a personal computer

(PC) running the Microlife Blood Pressure A (BPA+) 

software.

The memory data can be transferred to the PC by connecting the

monitor via a cable.

If no download-voucher and cable is included download the BPA

software from https://www.microlife.com/technologies/connect/

bpaplus and use a Micro-USB cable.
9. Data Memory

This device automatically stores up to 99 measurement values for

each of the 2 users.
Viewing the stored values

Switch the lock switch 

AN

 to «unlock» position. Touch the M-pad

AK

 briefly. The display first shows «M» 

BM

 and an average value.

The device then switches to the last stored value.

Touching the «+» 

AM

 or the «-» 

AL

 pad repeatedly enables you to

move from one stored value to another. Touch the M-pad again to

exit the memory mode.
Memory full

 

Pay attention that the maximum memory capacity of 99 

memories per user is not exceeded. When the 99 memory 

is full, the oldest value is automatically overwritten with the 

100th value. Values should be evaluated by a doctor before 

the memory capacity is reached – otherwise data will be 

lost.

Clearing all values

1.   Firstly unlock the device, then select either 1 or 2 with the user 

pad 

9

.

2.   Hold down the M-pad 

AK

 until «CL» appears and then release 

the button.

3.   Touch the M-pad while «CL» is flashing to permanently clear 

all values of the selected user.

 Cancel deletion: press START/STOP pad 

1

 while «CL» is 

flashing.

 Individual values cannot be cleared.

10.Battery Indicator and Battery change

Low battery

When the batteries are approximately ¾ empty the battery symbol

BK

 will flash as soon as the device is switched on (partly filled

battery displayed). Although the device will continue to measure

reliably, you should obtain replacement batteries.
Flat battery – replacement

When the batteries are flat, the battery symbol 

BK

 will flash as

soon as the instrument is switched on (flat battery displayed).

You cannot take any further measurements and must replace the

batteries.

1.   Open the battery compartment 

5

 at the back of the 

instrument.

2.   Replace the batteries – ensure correct polarity as shown by 

the symbols in the compartment.

3.   To set date and time, follow the procedure described in 

«Section 3.».

  The memory retains all values although date and time must be 

reset – the year number therefore flashes automatically after 

the batteries are replaced.

Which batteries and which procedure?

  Use 4 new, long-life 1.5V, size AAA batteries.

 

Do not use batteries beyond their date of expiry.

 

Remove batteries if the instrument is not going to be used for 

a week or more.

Using rechargeable batteries

You can also operate this instrument using rechargeable batteries.

 

 Only use «NiMH» type reusable batteries.

  Batteries must be removed and recharged when the flat 

battery symbol appears. They should not remain inside the 

instrument as they may become damaged (total discharge as 

Summary of Contents for A7 Touch BT

Page 1: ...EN 1 Microlife BP A7 Touch BT A7Touch BT...

Page 2: ...Microlife BP A7 Touch BT Start Stop _...

Page 3: ...r want to order spare parts please contact Microlife Customer Service Your dealer or pharmacy will be able to give you the address of the Microlife dealer in your country Alternatively visit the Inter...

Page 4: ...Cleaning the cuff Accuracy test Disposal 14 Guarantee 15 Technical Specifications 1 ImportantFactsaboutBloodPressureandSelf Measurement Blood pressure is the pressure of the blood flowing in the arter...

Page 5: ...t and pump blood Atrial fibrillation occurs when rapid disorganized electrical signals are present in the heart s two upper chambers called the atria causing them to contract quickly fast and irregula...

Page 6: ...on The first person to measure should select user 1 Select the measuring mode standard or AFIBsensTM mode This device enables you to select either standard standard single measurement or AFIBsensTM MA...

Page 7: ...ssure sensation 5 AppearanceoftheAtrialFibrillationIndicatorforearly Detection onlyinAFIB MAMmode This device is able to detect atrial fibrillation AFIB This symbol BO indicates that atrial fibrillati...

Page 8: ...values 1 Firstly unlock the device then select either 1 or 2 with the user pad 9 2 Hold down the M pad AK until CL appears and then release the button 3 Touch the M pad while CL is flashing to permane...

Page 9: ...ERR 1 Signal too weak The pulse signals on the cuff are too weak Re position the cuff and repeat the measurement ERR 2 BS Error signal During the measurement error signals were detected by the cuff c...

Page 10: ...ections of this booklet Ensure that children do not use the instrument unsupervised some parts are small enough to be swallowed Device care Clean the instrument only with a soft dry cloth Cleaning the...

Page 11: ...urce 4 x 1 5 V Batteries size AAA Mains adapter DC 6V 600 mA optional Battery lifetime approx 400 measurements using new batteries IP Class IP20 Reference tostandards EN 1060 1 3 4 IEC 60601 1 IEC 606...

Page 12: ...w microlife com Asia Microlife Corporation 9F 431 RuiGuang Road NeiHu Taipei 11492 Taiwan R O C Tel 886 2 87971288 Fax 886 2 87971283 Email service microlife com tw www microlife com North Central Sou...

Reviews: