background image

2

Introduction

Congratulations on your purchase of a high quality, Microlene Twin Filter Housing Kit.  

All components have been designed and manufactured to provide reliable operation.

Model Selection

Davey offer our Microlene Twin Filter Housing Kits with two purchasing options:

KAS#J Models

 – Include preselected filters for treating harvested water, 20 micron for 

removal of dust and sediment, followed by 1 micron for finer sediment and cyst removal.

KAS#JM Models

 – Include a preselected 5 micron filter for light sediment removal 

and a 5 Micron Carbon Cartridge for taste and odour.

AS Models

 – Offer the option to select your own filters to suit your specific requirements.

The model selected should be based on the maximum water or peak flow rate required.

Summary of Contents for AS10A

Page 1: ... other property This unit is designed to filter the cold water line at ambient temperatures 0ºC to 50ºC The appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure they do not play with the appliance If installing on Australian Municipal water sources a dual check valve and back flow prevention device must be fitted pr...

Page 2: ...ns KAS J Models Include preselected filters for treating harvested water 20 micron for removal of dust and sediment followed by 1 micron for finer sediment and cyst removal KAS JM Models Include a preselected 5 micron filter for light sediment removal and a 5 Micron Carbon Cartridge for taste and odour AS Models Offer the option to select your own filters to suit your specific requirements The mod...

Page 3: ... C 57 lpm to suit single bathroom home AS10J 10 Jumbo Dual jumbo housing kit only Purchased separately 25mm 1 BSP Female 0 880kPa 0 40 C 0 50 C Max flow of 125 lpm subject to filter selection which generally lands close to 57 lpm KAS20J 20 Jumbo Dual jumbo filter pack including sediment removal filters 1 x 20 Micron poly pleated filter 20PP20J 1 x 1 Micron Poly Spun filter 1PS20J 25mm 1 BSP Female...

Page 4: ...uld be replaced immediately Date the bottom of any new or replacement housing to indicate the next recommended replacement date Special Notes For cold water use only Do not install where system will be exposed to direct sunlight Make certain that installation complies with all state and local laws and regulations The contaminants or other substances removed or reduced by the selected cartridge are...

Page 5: ...earby Installation above electrical equipment is not preferable as water loss during maintenance or in the event of a water leak could damage this equipment Mounting Plumbing and Start up The 10 Standard unit AS10A has 20mm 3 4 BSP female plumbing connections requiring 20mm 3 4 BSP male plumbing The 10 Jumbo and 20 Jumbo models AS10J KAS10J KAS10JM AS20J KAS20J and KAS20JM have 25mm 1 BSP female p...

Page 6: ...ly and replace If damage to the pleats is visable it should be replaced The stage two poly spun is not washable and requires replacement every 3 6 months depending on water quality It is always good practice to keep a spare set of filters on hand Activated Carbon Cartridge Filter Life available as an added option Fit into the stage two filter housing Readily available through your Davey dealer the...

Page 7: ...and hand tighten Do not over tighten Turn on water supply slowly to allow filter to fill with water Depress blue pressure relief buttons to release trapped air Flush cartridge for 5 minutes before use Flush again for 10 minutes before using water Check for leaks before leaving installation If leaks present tighten with spanner provided Troubleshooting 1 Leak between cap and bottom of filter housin...

Page 8: ...d by Davey on the basis of their product knowledge and reasonable judgement and will be accepted if a relevant defect is found the warranty claim is made during the relevant warranty period and none of the excluded conditions listed above apply The customer will be notified of the warranty decision in writing and if found to be invalid the customer must organise collection of the product at their ...

Reviews: