MHX-900 Operating Manual: Appendix A Modem Command Summary
19
A. Modem Command Summary
The following provides a command summary for the MHX-900 module. Factory settings are denoted with a ‘*’.
AT Commands
A
Answer
D
Dial
E
Command Echo
E0 No Echo
* E1 Command Echo
I
Identification
I0 Product Code
I1 Checksum
I2 ROM Checksum
I3 Product ID
I4 Not Supported
I5 Firmware Version
O
On-line Mode
Q
Quiet Mode
* Q0 Enables Result Codes
Q1 Disables Result Codes
V
Result Codes Display
V0 Display as Numbers
* V1 Display as Words
W
Connection Result
* W0 Reports DTE as CONNECT xxxx
W1 Reports computer (DTE) rate and wireless
rate between modems as CARRIER xxxx.
W2 Reports DCE as CONNECT xxxx
Z
Reset and load stored configuration
&C
DCD (Data Carrier Detect)
&C0 DCD is always on
* &C1 DCD is on when modems are
synchronized
&D
DTR (Data Terminal Ready)
&D0 DTR ignored
* &D2 DTR disconnects and switches to
command
&D3 DTR disconnects and resets modem
&F
Load Factory Default
&K
Handshaking
&K0 Disable Handshaking
* &K3 Enable Handshaking
&S
DSR (Data Set Ready)
&S0 DSR is always on
* &S1 DSR on in data, off in command mode
&V
View Configuration
&W
Write configuration to memory
Sxx?
Read S register value
Sxx=yy
Set S register value
Result Codes
0
OK
1
CONNECT
2
RING
3
NO CARRIER
4
ERROR
8
NO ANSWER
10
CONNECT 2400
11
CONNECT 4800
12
CONNECT 9600
14
CONNECT 19200
17
CONNECT 38400
18
CONNECT 57600
33
CONNECT 115200
S Registers
S0
Number of Rings - Auto Answer [0...255]
S2
Escape code [0...255] default ‘+’
S3
CR character [0...255] default <cr>
S4
Line Feed [0...255] default <lf>
S5
Backspace [0...255] default <bs>
S101
Operating Mode
1 - Master point to point
* 2 - Slave point to point
3 - Master point to multipoint
4 - Slave point to multipoint
S102
Serial Baud Rate
1 = 115200, 2 = 57600, 3 = 38400
4 = 28800, 5 = 19200, 6 = 14400
* 7 = 9600, 8 = 7200, 9 = 4800,
10 = 3600, 11 = 2400
S103
Wireless Link Rate
*1 = Turbo, 2 = Fast, 3 = Normal
S104
Network Address [0...65535]
S105
Unit Address [0...65535]
S106
Hopping Pattern [1...20]
S107
Encryption Key [0...65535]
S108
Output Power Level
* 0 = 1 mW, 1 = 10 mW, 2 = 100 mW
3 = 1000 mW
S109
Hopping Interval
1 = 25 msec, 2 = 50 msec, 3 = 100 msec,
4 = 150 msec, * 5 = 200 msec, 6 = 250 msec,
7 = 300 msec, 8 = 350 msec
S111
Packet Minimum Size [0...Maximum Size]
S112
Packet Maximum Size [1...255]
S113
Packet Retry Transmissions [0...255]
S114
Address Header
* 0 = Disabled, 1 = Binary, 2 = Text
S115
Packet Repeat Interval
1 = 1...1, 2 = 1...3, 3 = 1...7, 4 = 1...15
5 = 1...31, 6 = 1...63, 7 = 1...127, * 8 = 1...255
Summary of Contents for MHX-900
Page 2: ......
Page 4: ......
Page 24: ...20 MHX 900 Operating Manual Appendix A Modem Command Summary...
Page 26: ...22 MHX 900 Operating Manual Appendix B Serial Interface...
Page 28: ...24 MHX 900 Operating Manual Appendix C Sample Schematic Diagram...
Page 30: ...26 MHX 900 Operating Manual Appendix D Modem Setup Overview...
Page 32: ...28 MHX 900 Operating Manual Appendix E Technical Specifications...