3
DIPSWITCH CHART
DIP SWITCH CHART
X = OFF 1=ON
FUNCTION
1 2 3 4 5 6 7 8 9 10
X X X X X X X X X X
Sound Active
1 X X X X X X X X X
Auto (Beam)
1 1 X X X X X X X X
Auto (Animation)
X X 1 X X X X X X X
Slave
1
SET DMX ADDRESS FOR DMX MODE
1
DMX
DMX MODE
-
Before using the DMX512 controller, the channel address should be set. It can be set 001~511.Every binary address
switch has a digital number. Please refer to chart below.
No.
Digital No.
No.
Digital No.
1st
1
6th
32
2nd
2
7th
64
3rd
4
8th
128
4th
8
9th
256
5th
16
10th
Function switch
ILDA (PC CONTROL) MODE
-
To run the FIREFLY RGB in IDLA mode or (PC CONTROL MODE) simply connect your ILDA signal cable to the DB25
jack located on the rear of the unit, and the unit will automatically recognize. NOTE: when ILDA is connected, it
supersedes all modes.
4. MOUNTING AND INSTALLATION
Caution:
For added protection, mount the fixtures in areas outside walking paths, seating areas, or in areas were the fixture might
be reached by unauthorized personnel. Before mounting the fixture to any surface, make sure that the installation area can hold a
minimum point load of 10 times the device’s weight. Fixture installation must always be secured with a secondary safety attachment,
such as an appropriate safety cable. Never stand directly below the device when mounting, removing, or servicing the fixture.
Whether installing inverted on a truss or ceiling, or set on a flat level surface (see illustration below). Be sure this fixture is kept at
least 0.5m (1.5 ft) away from any flammable materials (decoration etc.). Always use and install the supplied safety cable as a safety
measure to prevent accidental damage and/or injury in the event the clamp fails.