DMX Modes

18CH Mode

Channel

Value

Function

1

000-255

Pan

2

000-255

Pan Fine

3

000-255

Tilt

4

000-255

Tilt Fine

5

000-255

Speed

6

000-004

Panel Rotation Cohesive beam

005-105

Panel Rotation Counter-clockwise

106-205

Panel Rotation Clockwise

206-255

Unlimited Panel Rotation

7

000-255

Dimmer

8

000-255

Strobe

9

000-255

Red

10

000-255

Green

11

000-255

Blue

12

000-255

White

13

000

No Function

001-019

Red & Green

020-039

Red & Blue

040-059

Green & Red

060-079

Green & Blue

080-099

Blue & Green

100-119

Red, Green & Blue

120-139

Red, Blue & Green

140-159

Green, Blue & Red

160-179

Red, Blue & Green

180-199

Blue, Red & Green

200-219

Green, Blue & Red

220-255

Red, Blue & Green

14

000-060

CH1-CH12 Valid

061-119

LED Bank01

120-159

LED Bank02

160-199

LED Bank03

200-255

LED Bank04

Summary of Contents for FENIX-WH

Page 1: ...USER MANUAL Please read this user manual before using this product NEORAY 120...

Page 2: ...all ares to see if it was damaged during transportation Please check whether the following items are included in the package Item Quantity NEORAY 120 fixture 1 Power cord 1 Bracket 1 Safety Cable 1 P...

Page 3: ...ave 50cm of free space around the device Note that heat sensitive objects may be deformed or damaged by the emitted heat of this fixture During operation the housing may become very hot Do not operate...

Page 4: ...CO Speed Z_MOTOR Dim Strobe Dim R Dim G Dim B Dim W Pattern Beam Macros MA_SPEED X Y_RUN Temp 00 0 Sense 000 Delay Time Lo_Init 000 Load Yes Rest Yes Work Mode PAN Inverse TILT Inverse Menu Test Back...

Page 5: ...Menu Display DMX Signal Master Signal MENU DOWN ENTER UP Slave Signal LCD DISPLAY Sound Signal...

Page 6: ...unting requires extensive experience including calculating working load limits A knowledge of the installation material being used and periodic safety inspection of all installation material and the f...

Page 7: ...ixtures together as a referred in the diagram below Always end your DMX 512 connection with at DMX terminator For installations where the DMX cable has to run for a long distance or as an electrically...

Page 8: ...7 000 255 Dimmer 8 000 255 Strobe 9 000 255 Red 10 000 255 Green 11 000 255 Blue 12 000 255 White 13 000 No Function 001 019 Red Green 020 039 Red Blue 040 059 Green Red 060 079 Green Blue 080 099 Bl...

Page 9: ...ur Fade 01 165 174 Colour Fade 02 175 184 Macro 01 185 194 Macro 02 195 204 Macro 03 205 214 Macro 04 215 224 Macro 05 225 234 Macro 06 235 255 Macro 07 16 000 255 Macro Speed slow to fast 17 000 063...

Page 10: ...E 10W 4 in 1 LEDs Lamp LED life 50 000Hrs Power input AC120V 50 60Hz 155W Power connection Powercon In Out Data connection 3 Pin XLR DMX Modes Auto Master Slave Sound DMX DMX Channels 18CH Colour s RG...

Page 11: ...technician Any safety issues must be resolved CAUTION Disconnect fixture before servicing In order to keep the fixture in good condition and extend the life we suggest regular cleaning to the fixture...

Page 12: ...For more information please contact www microhdj com info microhdj com 905 428 9062...

Reviews: