1.1 BOOSTER AMPLIFIER

The Model 160 Booster Amplifier is de-

signed to provide the capability to power addi-

tional Visual Pagers Model 920, 930, 940, 960 or

9600 Remote Displays. Each Model 160 can

power up to 45 digits of any combination of

Remote Displays depending on distance.

Additional Model 160 Boosters can be added

to the system providing the capability to power

a virtual limitless number of Remote Displays.

Installation consists of cabling either with

RG59/U, 18 AWG Paired Wire or 16 AWG

Paired Wire. Once installed, the Model 160

requires no maintenance or servicing.

There are (4) red LEDs located on the top of

the Model 160 that indicate normal operating

status. When first plugged  in, the Booster will

not indicate 

Sys Sig In

 until the Model 904 is

plugged in and turned ON.

The 

5VDC

 LED indicates the Model 160

Booster is plugged into the power adaptor and

connected to the AC, and the Keypad is also

plugged in and turned ON.  If this LED is not lit,

first check the connecting cable from the Key-

pad and ensure that the Keypad is turned ON.

Next, unplug the Booster and check the 2.5

Amp fuse.

If there is a shorted cable in the system, the

STATUS

 LED will flash indicating the system

needs to be turned OFF and the problem cor-

rected. Once the short is corrected, the 

STATUS

LED will remain steadily ON.

The

 

SYS SIG IN

 

and 

SYS SIG OUT

 

LEDs

indicate the Booster is receiving and transmit-

ting the number from the Keypad to the Remote

Displays.

1.2 PRE-INSTALLATION

Before permanent installation is made, we

recommend that you first test your system and

cables. This will be of great benefit in trouble-

shooting should you have any problems after

installation. Carefully unpack each part of your

system and record any shipping damage.

FIRST,

 place the Booster Amplifier next to

a 115 VAC outlet close to the Model 904 Keypad.

Plug both the Booster and Keypad in.

SECOND,

 connect a cable from the Signal

Out connector of the Model 904 Keypad to the

Input Connector on the Booster Amp. Turn on

the Model 904 and observe that the POWER and

SIGNAL LEDs located on the front of the Model

160 are ON.

THIRD

, connect a cable from the Output

Connector on the Booster to the Model 920, 930,

or 940 Remote Display.

FOURTH,

 enter a number into the Model

904 Keypad and see that it is displayed on the

Remote Display.

If there are any problems, proceed to the

Troubleshooting Chart  on page 10.  If there are

no problems, you are ready to install your

system.

1  PRODUCT DESCRIPTION/PRE-INSTALLATION

3 ea Model 940
Remote Displays

24 V

A

C

      Model 160
Booster Amplifier

                   Broken Arrow, OK 74011
                    

   1-800-635-3811

  2.5 

AMP

  Fast Blo

GMC Fuse

SIGNAL INPUT

SIGNAL

 INPUT

SYS SIG IN

SYS SIG OUT

5 VDC

STATUS

SOLID=NORM
BLINK= SHORT

SIGNAL OUT

GROUND

SIGNAL

 OUT

C  O  R  P  O  R  A  T  I  O  N

MICROFRAME

  ENTER 

DELETE

To ENTER a paging number, type its digits (press
DELETE if an error is made). Then press ENTER.
A Blinking light indicates a number is being entered.

To DELETE a paging number, press DELETE when the 
number is being displayed.

Visual-Pager Series 900

0

1

3

5

6

7

8

9

2

4

  115 TO 24 VAC
WALL MOUNTED
 TRANSFORMER

  115 TO 24 VAC
WALL MOUNTED
 TRANSFORMER

115 VAC

115 VAC

Model 904
Keypad

Model 160 
Booster Amp

160\ax\9702.ai

Summary of Contents for Series 160

Page 1: ...Microframe Corporation Series 160 BoosterAmplifier Operating Manual A0160 7011 A0160 7011...

Page 2: ......

Page 3: ...ECIFICATIONGUIDE ITEM NO A0160 7011 REVISION DATE 04 02 Microframe Corporation 604 S 12th Street Broken Arrow OK 74012 Tel 918 258 4839 Toll Free 1 800 635 3811 Website www microframecorp com E mail s...

Page 4: ...orp com Safety Do not install substitute parts or perform any modifi cationtotheproductwithoutfirstcontactingMicroframe Warning All power transformers line cords and electrical equipment should be kep...

Page 5: ...1 PRODUCT DESCRIPTION PRE INSTALLATION 7 1 1 BOOSTERAMPLIFIER 7 1 2 PRE INSTALLATION 7 2 INSTALLATION PROCEDURES 8 2 1 DETERMINE CONFIGURATION 8 2 2 ROUTING THE CABLES 8 2 3 DISPLAY INSTALLATION 8 INS...

Page 6: ...AC supply is not connected There are 3 RCA outputs and 3screwdownelevatorclamps to ease the installation pro cess Microframe Model 160 Booster Amp Model 940 DisplaysDistance 4 1200 5 800 6 600 7 500...

Page 7: ...fore permanent installation is made we recommend that you first test your system and cables This will be of great benefit in trouble shooting should you have any problems after installation Carefullyu...

Page 8: ...2 2 ROUTING THE CABLES All cable routing should be as straight as possible with no severe bends that may cause kinking 2 INSTALLATION PROCEDURES SIG IN 160 AX 9701 drw 1 1 2 AMP FAST BLO BLACK RED INP...

Page 9: ...ing number type its digits press DELETE if an error is made Then press ENTER A Blinking light indicates a number is being entered To DELETE a paging number press DELETE when the number is being displa...

Page 10: ...oster Booster not connected to AC 24v AC line fuse blown in Booster Note The power fuse is located on Rear Panel Shorted output cable Shorted Remote Display Normal Operation Turn ON Model 904 Check ca...

Page 11: ...11 MicroframeCorporation Series 160...

Page 12: ......

Reviews: