Visual-Pager® Display Detailed Operation
Configuration, Mode Settings continued…
o
Roll-Over Time Setting
The Roll-Over Time is the time each number in the display memory is shown before
changing to the next number. This time can be set from 1 to 9 seconds. To set this
time, send a page to Pager 9999 with the message “01_0X” where X is a number 1-9
representing the number of seconds.
o
Auto Delete Setting
The display can be set to automatically delete a number from its memory after a preset
time. NOTE: If you have a MultiPage Transmitter, use the transmitter's auto delete
rather than the display's auto delete time. To set the auto delete time, send a page to
Pager 9999 with the message “02_XX” where XX is a number from 1 to 42
representing the number of minutes to wait before auto deleting.
o
Chime Setting
If you have purchased an optional triac circuit, it can be activated every time a new
number is sent to the display. The duration of the triac output can be controlled by
changing this option. To change this option, send a page to 9999 with the message
“03_XX” where XX is a number from 00 to 99 representing the number of 0.1 second
intervals that you want the output to be on (i.e. 99=9.9 seconds). Sending a 00 will
cause the triac circuit to be disabled.
o
Clear All Numbers Command
There are occasions where you may want to clear all numbers from all displays. To
clear all numbers, send a page to Pager 9999 with the message “99_98.”
o
Reset Factory Defaults
To change the display settings back to factory defaults send a page to Pager 9999
with the message “99_99.”
o
Using the Display with Alternate Transmitters
The Visual-Pager® Display has been designed to work optimally with the MultiPage
Transmitter. However, in rare cases you may want to use the display with a transmitter
other than the MultiPage. If so, you can control the display's basic functions by
sending pages to the display’s address with beep types and messages to control the
function.
Beep Type “4” enters the number contained in the message into the display.
Beep Type “3” removes the number contained in the message from the display.
Example: to add "123" to display ID 1500, do the following. Send a page to Pager
1500 with beep type 4, message 123.