background image

 

 

 

Microframe Corporation 

 

 

 

 

 

 

 

10

 

604 South 12

th

 Street 

Broken Arrow, OK  74012 
800-635-3811 
www.microframecorp.com 

 

 

 

 

 

 

Series 3500 

Visual-Pager® Display Detailed Operation 

Configuration, Mode Settings continued… 
 

o

  Roll-Over Time Setting 

The  Roll-Over  Time  is  the  time  each  number  in  the  display  memory  is  shown  before 
changing to the next number.   This time can be  set from  1 to 9 seconds.    To set this 
time, send a page to Pager  9999  with  the  message  “01_0X” where X is a number 1-9 
representing the number of seconds. 
 

o

  Auto Delete Setting 

The display can be set to automatically delete a number from its memory after a preset 
time.    NOTE:  If  you  have  a  MultiPage  Transmitter,  use  the  transmitter's  auto  delete 
rather than the display's auto delete time.  To set the auto delete time, send a page to 
Pager  9999  with  the  message  “02_XX”  where  XX  is  a  number  from  1  to  42 
representing the number of minutes to wait before auto deleting. 
 

o

  Chime Setting 

If  you  have  purchased  an  optional  triac  circuit,  it  can  be  activated  every  time  a  new 
number  is  sent  to  the  display.    The  duration  of  the  triac  output  can  be  controlled  by 
changing  this  option.    To  change  this  option,  send  a  page  to  9999  with  the  message 
“03_XX” where XX is a number from 00 to 99 representing the number of 0.1 second 
intervals  that  you  want  the  output  to  be  on  (i.e.  99=9.9  seconds).    Sending  a  00  will 
cause the triac circuit to be disabled. 
 

o

  Clear All Numbers Command 

There  are  occasions  where  you  may  want  to  clear  all  numbers  from  all  displays.    To 
clear all numbers, send a page to Pager 9999 with the message “99_98.” 
 

o

  Reset Factory Defaults 

To  change  the  display  settings  back  to  factory  defaults  send  a  page  to  Pager  9999 
with the message “99_99.” 
 

o

  Using the Display with Alternate Transmitters 

The  Visual-Pager®  Display  has  been  designed  to  work  optimally  with  the  MultiPage 
Transmitter. However, in rare cases you may want to use the display with a transmitter 
other  than  the  MultiPage.    If  so,  you  can  control  the  display's  basic  functions  by 
sending pages  to the display’s  address with beep types and  messages to control the 
function.   
Beep Type “4” enters the number contained in the message into the display.  
Beep Type “3” removes the number contained in the message from the display. 
Example:  to  add  "123"  to  display  ID  1500,  do  the  following.    Send  a  page  to  Pager 
1500 with beep type 4, message 123. 

Summary of Contents for 3500 series

Page 1: ...th Street Broken Arrow OK 74012 Local 918 258 4839 Toll Free 800 635 3811 Website www microframecorp com E mail support microframecorp com SERIES 3500 MultiPage System INSTALLATION and SPECIFICATION GUIDE Manual No B3011 7013 Revision Date 02 2013 Control 1 1 ...

Page 2: ...ust use plenum rated cable The cable supplied from Microframe is rated CL2 and is approved for indoor installation everywhere except plenum areas Life Support Policy Microframe s products are not authorized for use as components in life support devices or systems without the express written approval of the President of Microframe Corporation As used herein 1 Life support devices or systems are def...

Page 3: ...SpecificationGuide Table of Contents MultiPage System Overview and Features 4 MultiPage System Instructional Diagram 5 MultiPage Transmitter Features and Operation 6 Visual Pager Display Features and Operation 8 Visual Pager Display Detailed Operation 9 Pocket Pager 2 Operation 11 Nexus Pager Operation 12 Slimline Pager Operation 13 Affinity Pager Operation 14 ...

Page 4: ...isual Pager Display has been designed to receive signals from the MultiPage Transmitter The display is available in a 2 3 4 or 6 digit model each of which has 5 5 tall red LED numbers Numbers sent to the display will be saved and shown on both the transmitter and the display until manually deleted or auto deleted depending upon user preference To enter a number on the Visual Pager display type the...

Page 5: ... to Im m ediately send the Page Press ENTER to Move to the Message Screen ENTER MESSAGE 567 ENTER SEND OR Pressing ENTER or SEND will send the page Re Paging 123 To cancel a re page or a displayed number Display 123 Re Paging 123 CANCEL Ready Cancel 123 ENTER SEND Pressing ENTER deletes the num ber from the W ireless UHF Display Pressing SEND deletes the num ber from the re paging queue Display 12...

Page 6: ...e options simply press SETUP on the keypad then press the or keys to move through the list of options When you come to an option you would like to change press ENTER Depending on the option you can either press the and keys to change the value of the option or you can use the numbers to type in the desired value To return to the main options menu press ENTER When finished making changes simply pre...

Page 7: ... accordingly NOTE Pager Base ID can only be changed at the factory OPTION 6 Baud Rate This is the rate at which the digital communications takes place in your system It is recommended that users do not change this setting If you change this number the display and pager settings will have to be changed accordingly NOTE Pager Baud Rate can only be changed at the factory OPTION 7 Out of Range This fe...

Page 8: ... the display using the MultiPage Transmitter 2 The display can also be used as a Pager Confirmation System In this mode the display shows the number of every vibrating pager that has been paged Operation Mode 1 Using the MultiPage Transmitter simply type in a number and press ENTER to send that number to the display To delete a number from the display simply press CANCEL then type the number follo...

Page 9: ... ready to communicate with a MultiPage Transmitter Base ID 0500000 Baud Rate 1200 The display will intelligently communicate with other settings by doing the following Press the button on the back of the display one time The display will show vertical bars Next page Pager number 1 with a beep type of 2 and message 7337 The display should change to horizontal bars to signify that it has learned the...

Page 10: ...riac output can be controlled by changing this option To change this option send a page to 9999 with the message 03_XX where XX is a number from 00 to 99 representing the number of 0 1 second intervals that you want the output to be on i e 99 9 9 seconds Sending a 00 will cause the triac circuit to be disabled o Clear All Numbers Command There are occasions where you may want to clear all numbers ...

Page 11: ...brating after approximately eight seconds If the user would like to stop the vibration before the eight seconds simply press the LARGE BLACK BUTTON If a numeric message is sent to the pager the message will be visible on the pager s LCD screen until the pager stops vibrating To view the message after the pager has stopped vibrating press the LARGE BLACK BUTTON once Sending a Group Call Page All pa...

Page 12: ...D BUTTON on the side of the pager If a numeric message is sent to the pager the message will be visible on the pager s LCD screen until the pager stops vibrating To view the message and turn off the flashing lights press the RED BUTTON three times Sending a Group Call Page All pagers respond to call number 900 unless another group call number has been chosen by the customer and programmed at the f...

Page 13: ...ammed to flash and vibrate for 3 minutes To change the alert mode follow these instructions Remove all the pagers from the charging unit or unplug the power supply that is connected to the charging base Wait for the demo page to stop about 7 seconds Press 1248 followed by SEND and ENTER For the message enter the code that corresponds to the alert that you want see below For example if you want the...

Page 14: ... By default the pagers are programmed to flash and vibrate for 8 seconds To change the alert mode follow these instructions Remove all the pagers from the charging unit or unplug the power supply that is connected to the charging base Wait for the demo page to stop about 7 seconds Press 1248 followed by SEND and ENTER For the message enter the code that corresponds to the alert that you want see b...

Reviews: