Microengine XP-GT Series Programming Manual Download Page 51

 

 

51

 

 

MicroEngine 

®

 

XP-GT/GTR Programming Manual

v4.00

 

 
 

 

 

Sensor Arm TZ 

 

Enter Input No.[?] 
(Min=01, Max=02) 

 

Arming TZ: [FF] 

 

 

- OK

 

X - Cancel 

 

5.1.5 View Sensor State 

This menu lets users view the sensor state; whether connected or not connected. 
 
To view the state of the sensors, please follow steps below: 
 

1.  Enter Configuration Menu. 

2. Press 

5

 for 

Alarm Menu

3. Press 

1

 for 

Input Setting

4. Press 

5

 for 

View Sensor State

. Screen as below will be shown. If the sensor 

is not connected, 

[E] 

will be shown. If the sensor is connected to the alarm 

panel, 

[N] 

will be shown. Press 

 

to return to 

Input Setting

 

 

View Sensor State 

 

Current Sensor State 

 

S[E] S[E] S[E] S[E] 

 

 

- OK

 

X - Cancel 

 

5.2 Output Setting 

 

5.2.1 Output On/Off 

This menu lets users toggle the selected output to be on or off. 
  
To toggle the output on or off, please follow steps below: 
 

1.  Enter Configuration Menu. 

2. Press 

5

 for 

Alarm Menu

3. Press 

2

 for 

Output Setting

4. Press 

1

 for 

Output On/Off

. Screen as below will be shown. Enter from 

1

 to 

4

 

to select the alarm output. Press 

 or 

 to toggle the output ON or OFF. Press 

 to save changes. 

 

 

Output On/Off 

 

Switch Output No.[?] 

 

(Min=01, Max=04) 

 

Status : [OFF] 

 

 

- OK              

X – Cancel

 

 

Summary of Contents for XP-GT Series

Page 1: ...1 MicroEngine XP GT GTR Programming Manual v4 00 XP GT GTR SINGLE DOOR ACCESS CONTROL SYSTEM PROGRAMMING MANUAL Version 4 00...

Page 2: ...ed arrangements and drawings 2 10 17 7 2008 Updated drawings and included the XP GTR series to the manual Also added a page to indicate scope of manual 3 00 20 7 2009 Updated System Menu added Alarm M...

Page 3: ...ming Manual v4 00 Scope This manual covers the following products 1 XP GT1200 2 XP GT3200 3 XP GT1200L 4 XP GT3200L 5 XP GTR1200 6 XP GTR3000 7 XP GTR1200L 8 XP GTR3000L 9 XP GT3500L 10 XP GT3500ABL 1...

Page 4: ...nment 10 i Configuration Menu Layout 10 ii Keypad Functions 10 iii Entering Configuration Mode 10 1 System Menu 13 1 1 Set Date and Time 13 1 2 Door Parameter 15 1 3 Time Set 20 1 4 Time Zone 22 1 5 H...

Page 5: ...3 General Wiring for two XP GT using MAS RBT 57 Appendix 4 Connection for XP GT using Sounder Feature 58 Appendix 5 Connection for XP GTR using Sounder Feature 59 Appendix 6 Connection for XP GT and...

Page 6: ...ow the steps below 1 Turn ON the power supply The screen below will be shown MicroEngine XP GT3200L v3 00 Starting up 2 While the controller is starting up press the button 3 Press to ColdStart the sy...

Page 7: ...es The controller can be operated in several verification modes for door access To set the verification modes for individual users refer to Section 2 4 Edit User Setting under Edit Verification Mode s...

Page 8: ...alled via the Database Menu will have a default pin number of 1234 To change the pin number please refer to Section 2 4 Edit User Setting c Token Fingerprint Mode Alternatively users can opt to use th...

Page 9: ...e consecutive times The failure can be caused by wrong pin number wrong time zone or anti pass back violations High Security Mode High Security Mode enabled Users need to Enabled comply with the pre s...

Page 10: ...number pin number or numeric value for certain functions 3 Press X to cancel a function or return to the previous screen 4 Press to select a parameter to change confirm a setting or value 5 Press or t...

Page 11: ...for enhanced security levels 4 Screen as below will be shown Re enter the same new 6 digit Master Pin 5 To enter Configuration Menu from here onwards press the asterisk key followed by the new 6 digit...

Page 12: ...3 Event Type 2 Output Type 1 Output On Off 3 Trigger Delay 2 Arm Delay 3 Panel Status 2 Output Setting 1 Input Setting 5 Alarm Menu 5 Show Information 4 Show Version 3 Test Watchdog 2 Clear Transactio...

Page 13: ...Cancel 8 Sounder Setting 6 General Parameter 5 Holiday Setting 3 Time Set Setting 4 Time Zone Setting 1 System Menu 1 Set Date Time Lock Release Time Door Open Time Lock Release TZ Exit Button TZ Auto...

Page 14: ...OK X Cancel XP GT GTR 1500L 3500L 1500ABL 3500ABL Series To program the date and time setting please follow steps below 1 Enter Configuration Menu 2 Press 1 for System Menu 3 Press 1 for Set Date Time...

Page 15: ...Menu 2 Press 1 for System Menu 3 Press 2 for Door Parameter 4 Press or to navigate the pointer to the desired parameter 5 Press to edit the settings followed by the desired setting values and again t...

Page 16: ...se the door lock for free access Value 00 50 Default value 00 No free access iv Exit Button Time Zone Description Time Zone setting for Exit Button This will determine the day of the week and the time...

Page 17: ...controller will sound buzzer when the cover is pried open Value ON OFF Default value OFF x Hi Security Mode Description High Security mode selection Users can choose one of the 3 modes for additional...

Page 18: ...der is triggered Value 00 99 Default value 00 NOTE Sub menu xv is only available to all GTR 1200 3000 1200L 3000L 1500L 1500ABL series only xvi GP Output Mode Description GP Output Mode selection User...

Page 19: ...time If disabled the both leafs must be opened at the same time otherwise one leaf will be locked once the other leaf is opened Value NO YES Default value NO xxi Reader Type Description Reader Type se...

Page 20: ...ed functions Time Set Time Zone Functions Time Set Time Zone Functions attached assigned Examples of Time Zone controlled functions are Auto Lock Release Card PIN Exit Button AutoPIN Hi security Mode...

Page 21: ...0 to 08 29 12 01 to 12 59 17 31 to 23 59 The Time Set will be programmed as follows Time Set 03 From To Interval 1 00 00 08 29 Interval 2 12 01 12 59 Interval 3 17 31 05 59 Here the timestamp interval...

Page 22: ...ges OK X Cancel NOTE Functions requiring same time intervals can reuse existing Time Sets 1 4 Time Zone A Time Zone consists of assigned Time Sets for the week one Time Set for each day of the week pl...

Page 23: ...ock release the whole day Time Set 00 The Time Zone should be configured as below Time Zone 02 Sun Mon Tue Wed Thu Fri Sat Hol Time Set 00 02 02 02 02 02 00 00 Time Set numbers refer to EXAMPLE 1 for...

Page 24: ...TimeZone Number Min 02 Max 99 00 OK X Cancel 4 Enter Time Zone number that users want to set Screen as below will be shown Time Zone Setting Time Zone No 03 S 00 M 00 T 00 W 00 T 00 F 00 S 00 H 00 OK...

Page 25: ...ber which in this case is 00 All functions that utilized the Time Zone will operate according to Holiday s Time Set setting during holiday dates To program the holiday setting please follow steps belo...

Page 26: ...nce Comm OFF Facility Code 0000 System Mode DA OK X Cancel 4 Press or to navigate the pointer to the desired parameter 5 Edit the values for the parameter by pressing followed by the desired value and...

Page 27: ...a table showing the features available and unavailable for each mode Features not stated here are supported by all modes Features Door Access Time Attendance 1 Number of relay boards supported 1 0 2 T...

Page 28: ...bit format instead NOTE Sub menu viii is only available for GT GTR 1500L 3500L series only ix Swap Card for Mifare Card This parameter lets users select whether the controller will be reading the Mif...

Page 29: ...e shown Enter the IP Address for the remote server and press to proceed to the next screen Network Settings Enter Remote IP Addr 192 168 001 100 OK X Cancel 6 The screen below will be shown Enter the...

Page 30: ...ers program the sounder to activate at a specific time of the day It can be programmed to activate up to 3 times a day and different time configurations can be implemented for different days of the we...

Page 31: ...a total of 62 events as shown in Table 1 and up to 10 events can be selected To program the O P trigger events please follow steps below 1 Enter Configuration Menu 2 Press 1 for System Menu 3 Press 9...

Page 32: ...Tamper On 6 Reader Down M Alarm On c Card Enabled s Main Fail 7 Controller Reset N Alarm Off d Pulse Door Open t Mains Normal 8 Enter Prog Mode O Door Security e Door Open u Power Low 9 Exit Prog Mode...

Page 33: ...er Screen as below will be shown Quick Add User Enter User Type User Type 0 Prox Card OK X Cancel Select the user type in this screen The four available options are i 0 for Prox Card ii 1 for ID No ii...

Page 34: ...ation To add user please follow steps below 1 Enter Configuration Menu 2 Press 2 for Database menu 3 Press 2 for Add User The screen below will be shown Add User Enter User Type User Type 0 Prox Card...

Page 35: ...Add User Allow 1 N Operation 1 N No OK X Cancel 7 Screen as below will be shown Select the verification mode for the new user by specifying the number corresponding to the verification mode 1 0 is by...

Page 36: ...To delete a user please follow steps below 1 Enter Configuration Menu 2 Press 2 for Database Menu 3 Press 3 for Delete User Screen as below will be shown Enter the user ID to specify the user to be de...

Page 37: ...User No ID OK X Cancel 4 Screen as below will be shown Enter the pre set Time Zone to grant door access for this user Press to proceed to the next screen Edit User Setting Edit TimeZone No TimeZone 01...

Page 38: ...ew Pin No for this user and press to proceed to the next screen 6 The screen below will be shown Select whether to allow the user to access Configuration Menu A success notification will appear to not...

Page 39: ...Cancel 4 Screen as below will be shown when the controller is clearing all user s antipassback statuses A success notification will be shown once all the antipassback statuses are cleared Clear AntiPa...

Page 40: ...user database CAUTION This process is irreversible Proceed only if users confirm to remove data of all users To clear all user data please follow steps below 1 Enter Configuration Menu 2 Press 2 for...

Page 41: ...Menu 2 Press 3 for Fingerprint Menu 3 Press 1 for Add Fingerprint Screen as below will be shown Enter the specified User ID Press to proceed to the next screen Add Fingerprint Enter User ID ID OK X C...

Page 42: ...L Ring 4 R Little 9 L Little Table 2 finger index representation 6 Screen as below will be shown to prompt user to place the finger on the sensor surface Please place designated finger on the sensor...

Page 43: ...dex of the user s fingerprint A success notification will be prompted to notify users when the template has been deleted Delete Fingerprint Enter Template Index 1 5 Template Index 0 All User Template...

Page 44: ...rint Menu 3 Press 4 to view Template Enrolled Screen as below will be shown Templates Enrolled Templates Enrolled 0288 OK X Cancel 3 5 Set Security Level This menu lets users set the security level of...

Page 45: ...Programming Manual v4 00 4 Screen as below will be shown Press to save Security Level Press to save Security Level 1 OK X Cancel NOTE Menu 3 5 Set Security Level is only available to XP GT 1200 3200...

Page 46: ...Screen as below will be shown Enter the new six digits Master PIN Press to proceed to the next screen Change Master Pin Enter New Master Pin Pin OK X Cancel 4 Re enter the new six digits Master PIN P...

Page 47: ...ions Press to proceed OK X Cancel 4 The transaction database will be cleared 4 3 Test Watchdog The test watchdog function is used to test whether the internal watchdog is in good condition to ensure t...

Page 48: ...intenance Menu 3 Press 4 for Show Version Screen as below will be shown and users will automatically return to Maintenance Menu after 4 seconds Maintenance Menu MicroEngine XP GT1200 v1 01 08 2007 OK...

Page 49: ...below will be shown Press 1 or 2 to select the sensor Press or to arm or disarm the input and press to save changes Arm Disarm Sensor Enter Input No Min 01 Max 02 Status Disarm OK X Cancel 5 1 2 Arm D...

Page 50: ...Setting 4 Press 3 for Trigger Delay Screen as below will be shown Press 1 or 2 to select the sensor Press to confirm and proceed to set the trigger delay time Enter duration between 0000 and 3599 in...

Page 51: ...E will be shown If the sensor is connected to the alarm panel N will be shown Press to return to Input Setting View Sensor State Current Sensor State S E S E S E S E OK X Cancel 5 2 Output Setting 5 2...

Page 52: ...he section to the right enter from 0000 and 3599 in seconds to specify the duration to activate the output alarm Press to save changes 5 2 3 Event Type This menu lets users specify the event type to t...

Page 53: ...ceed to set the time zone to activate the alarm output Press to save changes Output TZ Switch Output No Min 01 Max 04 Output TZ 00 OK X Cancel 5 3 Panel Status This menu lets users view the status of...

Page 54: ...Menu If the controller does not receive input for 30 seconds inside Configuration Menu the controller will automatically exit from Configuration Menu and return to Idle Mode Users can also exit Confi...

Page 55: ...55 MicroEngine XP GT GTR Programming Manual v4 00 Appendix 1 General Wiring for XP GT using MAS RBT XP GT GTR 1200 3000 3200 1200l 3000L 3200L...

Page 56: ...56 MicroEngine XP GT GTR Programming Manual v4 00 Appendix 2 General Wiring for XP GTR using MAS RBU XP GT GTR 1200 3000 3200 1200l 3000L 3200L...

Page 57: ...57 MicroEngine XP GT GTR Programming Manual v4 00 Appendix 3 General Wiring for Two XP GT using MAS RBT XP GT GTR 1200 3000 3200 1200l 3000L 3200L...

Page 58: ...58 MicroEngine XP GT GTR Programming Manual v4 00 Appendix 4 Connection for XP GT using Sounder Feature XP GT GTR 1200 3000 3200 1200l 3000L 3200L...

Page 59: ...59 MicroEngine XP GT GTR Programming Manual v4 00 Appendix 5 Connection for XP GTR using Sounder Feature XP GT GTR 1200 3000 3200 1200l 3000L 3200L...

Page 60: ...60 MicroEngine XP GT GTR Programming Manual v4 00 Appendix 6 Connection for XP GT and XP GTR using Fire Release Feature XP GT GTR 1200 3000 3200 1200l 3000L 3200L...

Page 61: ...61 MicroEngine XP GT GTR Programming Manual v4 00 Appendix 7 Connection for XP GTR to MIO44 XP GT GTR 1200 3000 3200 1200l 3000L 3200L...

Page 62: ...62 MicroEngine XP GT GTR Programming Manual v4 00 Appendix 8 General Wiring for XP GT using MAS RBM XP GT GTR 1500L 3500L 1500ABL 3500ABL...

Page 63: ...63 MicroEngine XP GT GTR Programming Manual v4 00 Appendix 9 General Wiring for XP GT using MAS RBU XP GT GTR 1500L 3500L 1500ABL 3500ABL...

Page 64: ...64 MicroEngine XP GT GTR Programming Manual v4 00 Appendix 10 Wiring Connection for Two XP GT using MAS RBM XP GT GTR 1500L 3500L 1500ABL 3500ABL...

Page 65: ...65 MicroEngine XP GT GTR Programming Manual v4 00 Appendix 11 Wiring Connection for XP GT using Sounder Feature XP GT GTR 1500L 3500L 1500ABL 3500ABL...

Page 66: ...66 MicroEngine XP GT GTR Programming Manual v4 00 Appendix 12 Wiring Connection for XP GTR using Sounder Feature XP GT GTR 1500L 3500L 1500ABL 3500ABL...

Page 67: ...67 MicroEngine XP GT GTR Programming Manual v4 00 Appendix 13 Wiring Modification for XP GT to Connect to Fire Alarm Signal with Voltage Source Wet Contact XP GT GTR 1500L 3500L 1500ABL 3500ABL...

Page 68: ...68 MicroEngine XP GT GTR Programming Manual v4 00 Appendix 14 Wiring Modification for XP GTR to Connect to Fire Alarm Signal with Voltage Source Wet Contact XP GT GTR 1500L 3500L 1500ABL 3500ABL...

Reviews: