![Microengine XP-GT Series Programming Manual Download Page 25](http://html1.mh-extra.com/html/microengine/xp-gt-series/xp-gt-series_programming-manual_1786366025.webp)
25
MicroEngine
®
XP-GT/GTR Programming Manual
v4.00
1.5 Holiday Setting
Holiday Setting
is used to define dates that are declared as holidays. The controller
has 30 sets (00-29) of Holiday settings.
When a date falls in the holiday category, its original Time Set setting in the Time Zone
will be overridden by the holiday’s Time Set setting in the same Time Zone.
EXAMPLE 5
Supposed 01 Jan falls on Thursday and the Time Set number for Thursday is 02. But
because 01 Jan is a holiday, the Time Set number is overridden by holiday’s Time Set
number, which in this case is 00.
All functions that utilized the Time Zone will operate according to Holiday’s Time Set
setting during holiday dates.
To program the holiday setting, please follow steps below:
1. Enter Configuration Menu.
2. Press
1
for
System Menu
.
3. Press
5
for
Holiday Setting
. The screen as below will be shown:
Holiday Setting
Enter Holiday Record
(Min = 00, Max = 29)
[00]
√
- OK
X – Cancel
4. Enter holiday number (“00-29”) that users want to set. Press
√
to confirm. The
screen below will be shown:
5. Enter the ‘MONTH’ setting. Press
↓
to proceed to the next section.
6. Enter the ‘DAY’ setting and press
√
. Screen as below will be shown:
Holiday Setting
Save Changes?
√
- OK
X - Cancel
7. Press
√
to save changes.
Holiday No 05
Month (00) Day (00)
Holiday Setting
√
- OK