Prompting
Chapter 10
))))))))))))))))))))))))))))))))))))))))))))
))))))))))))))))))))))))))))))))))))))))))))
470 Operators Manual
84
Since all transfers to fields are appends, it may be necessary to clear field data prior to a
transfer.
^A
^D
Command
148
Clear Operational Buffer Data:
149
Clear Field Data:
150
Clear Text Segment Data:
10.2 PROMPTING COMMANDS
^A
^D
Command
XX...
120
Load Prompt Control Word #1:
XX is the data for the prompt status word. The
format is ^AB1111111111111111^D120
5
.
XX...
124
Load Prompt Control Word #2:
XX is the data for prompt status word 2. The
format is ^AB1111111111111111^D124
5
.
121
Prompt First Line of Display:
This command is usually sent after the status
word. It displays a string in the first line of the LCD display. The input accepted
is determined by the status word. To use this function send ^D121
5
"STRING"
5
.
122
Buffer Prompt:
Load buffer mode prompting information. This data must be
terminated by a ^W.
XX
123
Load Number of Times:
XX is the number of iterations of the prompting cycle.
Special Notes about prompting:
*
While in prompt mode, press <SHIFT> <SHIFT> <SHIFT> <CLEAR> to erase any text
on the 2nd LCD line.
*
The 470 will start at the beginning of a prompt list and execute each command in
sequence. This prompt list is stored using ^D122
5
followed by the prompt list and
ending with a ^W.
*
There is a 40 character text limit on keyboard entry.
*
Label field length should be set appropriately to avoid incorrect print.