PAC1921 High-Side Current/Power Sensor Evaluation Board User’s Guide
DS50002376A-page 24
2015 Microchip Technology Inc.
Jumper settings are described in
3.6
TEST POINTS
The PAC1921 High-Side Current/Power Sensor Evaluation Board provides test points
for ground reference and signal access.
summarizes these test points.
TABLE 3-2:
JUMPER SETTINGS
Pin
Header
Label
Default Position
Alternate Position(s)
J1, J2
, Vsource-
External power source terminals. (See
Section 3.8.2 “Load Connection”
.)
J3, J4
Demo Sys
Select Demo mode R
SENSE+/-
.
Positions 3-2 are jumpered on both
jumpers. (See
Select Sys mode R
SENSE+/-
.
Positions 1-2 are jumpered on both
jumpers. (See
J5, J6,
J7
Reserved
Reserved for future use
J8
J8 (ADDR_SEL)
(See
)
In SMBus mode, sets SMBus address to
1001_100b
at power-up.
Positions 1-2 are jumpered.
In SMBus mode, sets SMBus address to
1001_101b
at power-up.
Positions 2-3 are jumpered.
J11
GND
Connect ground from external source for
Sys mode.
J13
GND, #READ/INT,
SMBus_DATA,
SMBus_CLK, VDD
USB bridge generates on-board 3.3V
and provides SMBus host.
Positions 1-2, 3-4, 5-6, 7-8, 9-10 are all
jumpered.
(See
.)
TABLE 3-3:
TEST POINTS
Test Point
Marking
Signal Function Monitored
1
(orange)
SENSE+
2
Vsense- (yellow)
SENSE-
3
OUT (white)
OUT Pin
4
ADDR_SEL
SMBus Address Select
5
Vdd (red)
V
DD
6
GND (black)
Ground
7
#READ/INT (yellow)
READ/INT Pin