GUI Description
2019 Microchip Technology Inc.
DS50002914A-page 23
4.2.4
I
2
C Monitor Status and Control Bar
The Status and Control bar contains the items listed in
.
FIGURE 4-4:
I
2
C Monitor Status and Control Bar.
In the Status and Control bar, the user can choose the hardware tool for communication
with the device and the settings it should allow.
In order to connect to a device, the user must follow the steps described in
. After connecting the Micro-USB cable,
the user must
scan for a valid address. Once a valid address is detected, clicking the
Connect
button
will initialize the connection with the device, and the registers will be available for read
and write operations.
TABLE 4-1:
MONITOR STATUS AND CONTROL BAR
Item
Description
Addr
This drop-down menu shows the address of the available devices.
Connector
This drop-down menu shows the type of connector used to connect the board.
ScanAddr
This button is used to scan for a valid address.
Connect/Disconnect
These buttons are used to connect/disconnect the current selected device.
Voltage
This drop-down menu is used to select the voltage level of the communication when using
the PICkit™ Serial Analyzer.
)
Rate
This drop-down menu is used to select the corresponding communication rate for the
device.
Pull Ups
This drop-down menu is used to activate the internal pull-ups from the PICkit
Serial Analyzer.
(
Note 1:
Optional. PICkit Serial Analyzer should first be connected on the I
2
C pin header on the MIC33M656
Evaluation Board.