6 CHANGE OVER PROCEDURE
6.1 ADJUSTING THE FILLER
1.
Fill 6 cans with water or product to the desired volume/weight, and place
them under the filling station.
2.
Go the filling station screen on your HMI panel, and lower the filling station
so that the fill tubes and float switches are inside the cans.
3.
Loosen the set screw (shown red below) on each collar. Move the collar up
or down until the sensor light is activated on the HMI screen. Then tighten the
set screw. Repeat for each can/station.
4.
Use the HMI screen to raise the fill station.
5.
Remove setup cans so the machine will be ready to run.